Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CARDINGTON YUTAKA TECHNOLOGIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CARDINGTON YUTAKA TECHNOLOGIES, INC. in 575 WEST MIAN ST., CARDINGTON, OH 43315 (NAICS 336399). OSHA activity number 337546816.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cardington Yutaka Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Cardington Yutaka Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
575 WEST MIAN ST.
City
CARDINGTON
State
OH
ZIP
43315
Mailing
575 WEST MAIN ST., CARDINGTON, OH 43315
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
850
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 700 exposed
Issued
Apr 11, 2013
Abate by
Apr 18, 2013
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(7)(i):     The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    Cardington Yutaka Technologies, Inc., located at 575 West Main St., Cardington, OH 43315: On or about October 30, 2012, the employer failed to properly train employees to lockout/tagout Cat/Con Line 10 Water Leak Test # 1 (manufactured by Matumoto Sangyo Co., Ltd., Serial # 04S047) before employees conducted activities such as, but not limited to, unjamming or cleaning the machine. Employees were exposed to the unexpected startup of the machines moving parts while conducting work, and that could result in struck-by and caught-in injuries.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.147 D02

Serious Gravity 10 1 instance 700 exposed
Issued
Apr 11, 2013
Abate by
Apr 18, 2013
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(d)(2):     The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:    Cardington Yutaka Technologies, Inc., located at 575 West Main St., Cardington, OH 43315: On or about October 30, 2012, the employer failed to implement established energy control application steps to control hazardous energy of the Cat/Con Line 10 Water Leak Test # 1 (manufactured by Matumoto Sangyo Co., Ltd., Serial # 04S047) during a time employees accessed hazard areas of the machine. Employees were exposed to struck-by and caught-in injuries because the machines energy sources were not shut down and controlled prior to unjamming or cleaning the equipment.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.303 G01 I A

Serious Gravity 1 1 instance 700 exposed
Issued
Apr 11, 2013
Abate by
Apr 18, 2013
Penalty
Initial $3,300 · Current $3,000 Reduced
29 CFR 1910.303(g)(1)(i)(A):     For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    Cardington Yutaka Technologies, Inc., located at 575 West Main St., Cardington, OH 43315: On or about October 30, 2012, the employer failed to ensure a clearance of at least 3 feet in front of Cat/Con Line 10 Cover Assembly # 1 electrical cabinet (480V, 3-Phase; Number 160-330072) that is located adjacent to the Line 10 Cover Assembly # 1 cell. The electrical cabinet was blocked by a yellow cart that was used for the placement of defective parts.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3300

View Cardington Yutaka Technologies, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337546816.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.