Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CARDINGTON YUTAKA TECHNOLOGIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CARDINGTON YUTAKA TECHNOLOGIES, INC. in 575 WEST MAIN ST., CARDINGTON, OH 43315 (NAICS 336399). OSHA activity number 340923671.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cardington Yutaka Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Cardington Yutaka Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
575 WEST MAIN ST.
City
CARDINGTON
State
OH
ZIP
43315
Mailing
575 WEST MAIN ST., CARDINGTON, OH 43315
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
965
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 21, 2015
Abate by
Nov 16, 2015
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) Cardington Yutaka Technologies, Inc. on or about September 09, 2015, at the address of 575 West Main St. Cardington, OH: The employer failed to ensure that energy control procedures were utilized to control potentially hazardous energy sources while an employee performed a tool adjustment on the Double End Forming Machine (#320052) on line #6. Employees performing these adjustment activities in this condition were exposed to unexpected energization at or near the machines point of operation.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.147 D02

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 21, 2015
Abate by
Nov 16, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  a) Cardington Yutaka Technologies, Inc. on or about September 09, 2015, at the address of 575 West Main St. Cardington, OH: The employer failed to ensure that energy isolating procedures for shutdown were performed prior to conducting tool adjustments on the Double End Forming Machine (#320052) on line #6. Employees performing these task in energized condition were exposed to amputation hazards at or near the machines point of operation, in that energy control shutdown procedures required under 29 CRF 1910.147(d)(2) were not utilized before the employee began the aforementioned work task on the machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 21, 2015
Abate by
Nov 16, 2015
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) Cardington Yutaka Technologies, Inc. on or about September 09, 2015, at the address of 575 West Main St. Cardington, OH: The employer failed to ensure that employees who are responsible/tasked with service work at or near the point of operation on the Double End Forming Machine (#320052) were adequately evaluated for the skills required for the appropriate application and usage of machine specific energy control procedures. Employees performing service work in an energized condition were exposed to amputation hazards.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

View Cardington Yutaka Technologies, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340923671.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.