Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J&M ENERGY SERVICES

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of J&M ENERGY SERVICES in HORNET STATE 26 WELL #1, PECOS, TX 79772 (NAICS 213111). OSHA activity number 337756829.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J&M Energy Services — free Get an email when a new federal OSHA severe-injury report for J&M Energy Services is published. One employer, no account, unsubscribe in one click.
Establishment
J&M ENERGY SERVICES
Site address
HORNET STATE 26 WELL #1
City
PECOS
State
TX
ZIP
79772
Mailing
1705 S. STOCKTON, MONAHANS, TX 79756
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
100
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
May 17, 2013
Abate by
Jun 19, 2013
Penalty
Initial $3,850 · Current $3,000 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that:    Pulling Unit Rig #115, Lease: Hornet State 26, Well #1:  On or about December 7, 2012, employees were exposed to fall and potential fire hazards due to the Geronimo Line not being insatalled for auxilary escape at the rig location during servicing operations.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3850

1910.132 A

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 17, 2013
Abate by
Jun 13, 2013
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  On or about December 7, 2012, employer did not ensure that employees working at servicing a well were adequately protected from fire hazards by wearing flame resistant clothing.  Employees were exposed to potential fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5390

1910.1200 H01

Serious Gravity 1 1 instance 1 exposed
Issued
May 17, 2013
Abate by
Jun 13, 2013
Penalty
Initial $2,310 · Current $1,500 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    On or about December 7, 2012, employer did not ensure that effective information and training was provided to employees regarding the hazards of H2S and Natural Gas.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2310

1910.23 D01 III

Repeat Gravity 1 3 instances 1 exposed
Issued
May 17, 2013
Abate by
Jun 19, 2013
Penalty
Initial $4,620 · Current $3,500 Reduced
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side:    On or about December 7, 2012, on pulling unit rig #115, employer did not ensure that stairways were equipped with guard rails. Employees were accesing the service rig working platform through stairways without guard rail on one side. This condition exposed employees to potential falls and struck-by hazards.     J&M ENERGY SOURCES WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 312238967, CITATION NUMBER 1, ITEM NUMBER 1(a) AND WAS AFFIRMED AS A FINAL ORDER ON 11/06/2008, WITH RESPECT TO A WORKPLACE LOCATED AT WELL #1H, SHARAH LEASE, HWY 158, MIDLAND, TX 79701.
Recent events (2)
  • — I (R) $3500
  • — Z (R) $4620

View J&M Energy Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337756829.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.