Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J & M ENERGY SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J & M ENERGY SERVICES in WILKINSON RD, BIG SPRING, TX 79720 (NAICS 213112). OSHA activity number 345924385.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & M Energy Services — free Get an email when a new federal OSHA severe-injury report for J & M Energy Services is published. One employer, no account, unsubscribe in one click.
Site address
WILKINSON RD
City
BIG SPRING
State
TX
ZIP
79720
Mailing
1705 SOUTH STOCKTON AVENUE, MONAHANS, TX 79756
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
4
Ownership type
A

4 citations on file for this inspection.

1910.25 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 28, 2022
Abate by
Aug 25, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR  1910.25(b)(1): (1) Handrails, stair rail systems, and guardrail systems are provided in accordance with 29 CFR 1910.28;  On or about April 26, 2022, Employees engaged in performing well servicing operations were exposed to fall hazards in excess of four feet without the use of handrails.
Recent events (1)
  • — Z (S) $2486

1910.133 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 28, 2022
Penalty
Initial $2,113 · Current $2,113
29 CFR  1910.133(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  On or about April 26, 2022, Employees engaged in performing well servicing operations were exposed to stuck-by hazards from potential flying particles and liquid chemicals.
Recent events (1)
  • — Z (S) $2113

1910.134 H03 I B

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 28, 2022
Abate by
Aug 25, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR  1910.134(h)(3)(i)(B):All respirators maintained for use in emergency situations shall be inspected at least monthly and in accordance with the manufacturer's recommendations, and shall be checked for proper function before and after each use;  On or about April 26, 2022, Employees engaged in performing well servicing operations while maintaining emergency escape respirators on-site without updated monthly inspections.
Recent events (1)
  • — Z (S) $2486

1910.134 H04

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 28, 2022
Abate by
Aug 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(h)(4):Repairs. The employer shall ensure that respirators that fail an inspection or are otherwise found to be defective are removed from service, and are discarded or repaired or adjusted in accordance with the following procedures:  On or about April 26, 2022, Employees engaged in performing well servicing operations with defective emergency escape respirators on-site.
Recent events (1)
  • — Z (S) $0

View J & M Energy Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345924385.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.