BRIDGEVILLE, PA —
OSHA Inspection: UNIVERSAL STAINLESS & ALLOY PRODUCTS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of UNIVERSAL STAINLESS & ALLOY PRODUCTS INC. in 600 MAYER STREET, BRIDGEVILLE, PA 15017 (NAICS 331513). OSHA activity number 338062615.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL STAINLESS & ALLOY PRODUCTS INC.
- Site address
- 600 MAYER STREET
- City
- BRIDGEVILLE
- State
- PA
- ZIP
- 15017
- Mailing
- 600 MAYER STREET, BRIDGEVILLE, PA 15017
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 260
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.252 A02 IV
- Issued
- Jan 22, 2013
- Penalty
- Initial $3,400 · Current $3,400
General-duty citation text
29 CFR 1910.252(a)(2)(iv): Cutting or welding was permitted in areas before the areas were inspected by the individual responsible for authorizing cutting and welding operations (a) Facility, Creek Building, Bridgeville, PA: On or about 12/18/12 the employer's person responsible for authorizing cutting and welding operations did not conduct an inspection of the areas prior to the start of work to ensure the area was accessed for hazardous operations or conditions that might present a danger during this type of work.
Recent events (1)
- — Z (S) $3400
1910.252 A02 XIII D
- Issued
- Jan 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(a)(2)(xiii)(D): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment, and did not advise all contractors about flammable materials or hazardous conditions of which they may not be aware: (a) Facility, Creek Building, Bridgeville, PA: On or about December 19, 2012 the employer did not recognize its responsibility for the safe usage of cutting or welding equipment on its property and did not advise all contactors about flammable materials or hazardous conditions. The employer had not conducted an inspection of the workplace to access what combustibles, flammables or other potential hazards existed in the area prior to permitting cutting and welding by an outside contractor. The employer did not ensure the contractor understood what precautions needed to be taken when working in the area such as providing a fire watch or covering potential hazards in the work area. A fire occurred at the plate leveler from sparks and hot materials from the cutting operations and the contractor did not have a fire watch in effect nor was the area covered with fire blankets.
Recent events (1)
- — Z (S) $0
More inspections at Universal Stainless & Alloy Products INC.
View Universal Stainless & Alloy Products INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338062615.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.