On , OSHA opened a planned safety inspection of NORTH SOUTH MASONRY & TUCKPOINTING, INC. in 2700 W. ARGYLE STR., CHICAGO, IL 60625 (NAICS 238140). OSHA activity number 339028862.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch North South Masonry & Tuckpointing, INC. — free Get an email when a new federal OSHA severe-injury report for North South Masonry & Tuckpointing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2700 W. ARGYLE STR.
City
CHICAGO
State
IL
ZIP
60625
Mailing
1100 S. ALDINE AVE., PARK RIDGE, IL 60068
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

9 citations on file for this inspection.

1926.451 D03 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
May 6, 2013
Penalty
Initial $3,080 · Current $1,200 Reduced
29 CFR 1926.451(d)(3)(iv):  Counterweights were not secured by mechanical means to the outrigger beams to prevent accidental displacement:    a)  Employees were working from the two-point adjustable suspension scaffold system with counterweights not secured to the outrigger beams.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $3080

1926.451 D03 VI

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
May 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(3)(vi):  Outrigger beams which were not stabilized by bolts or other direct connections to the floor or roof deck were not secured by tiebacks:  a)  Employees were working from the two-point adjustable suspension scaffold supported by the outrigger beams which were not secured by tiebacks.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 D16

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
May 6, 2013
Penalty
Initial $2,200 · Current $860 Reduced
29 CFR 1926.451(d)(16): The suspension scaffold power-operated hoist or manually operated hoist did not have, in addition to the normal operating brake, a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed.     a)  Employees were working from the two-point adjustable suspension scaffold which did not have a breaking device or locking pawl.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $860
  • — Z (S) $2200

1926.451 D17

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
May 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(17):  Manually operated hoists did not have a positive crank force to descend:   a)  Employees were working from the two-point adjustable suspension scaffold where the manually operated hoist did not have a positive crank force to descend.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
May 6, 2013
Penalty
Initial $2,200 · Current $860 Reduced
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion:       a)  Vertical lifelines that were used by employees working from the two-point adjustable suspension scaffold were not fastened to a fixed safe point of anchorage.  Lifelines were not protected from abrasion and sharp edges of the parapet wall.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $860
  • — Z (S) $2200

1926.454 A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
Jun 3, 2013
Penalty
Initial $2,200 · Current $860 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:     a)  Employer did not provide training to each employee in order to recognize hazards associated with working from the two-point adjustable suspension scaffold and to understand procedures to control or minimize those hazards.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $860
  • — Z (S) $2200

1926.503 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
Jun 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee who might be exposed to fall hazards:     a)  Employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 30, 2013
Abate by
May 6, 2013
Penalty
Initial $3,080 · Current $1,200 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:     a)  Employees engaged in masonry work were not protected from hazards of falling, while working along unprotected edges of the roof with the ground to eave height of approximately 35 feet.       No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $3080

1926.501 B04 I

Serious Gravity 5 5 instances 3 exposed
Issued
Apr 30, 2013
Abate by
May 6, 2013
Penalty
Initial $2,640 · Current $1,020 Reduced
29 CFR 1926.501(b)(4)(i):  Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels by personal fall arrest systems, covers or guardrail systems erected around such holes:     a)  Employees were not protected from the hazard of falling approximately 12 feet to the lower level while performing masonry work around unguarded skylights.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).