BARRIGADA, GU —
OSHA Inspection: CONWOOD PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONWOOD PRODUCTS, INC. in 125 U S ARMY 1 C FEJRAN STREET, BARRIGADA, GU 96913 (NAICS 444190). OSHA activity number 339052748.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONWOOD PRODUCTS, INC.
- Site address
- 125 U S ARMY 1 C FEJRAN STREET
- City
- BARRIGADA
- State
- GU
- ZIP
- 96913
- Mailing
- 125 US ARMY JUAN C FEJERAN, BARRIGADA, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 25
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.36 D01
- Issued
- Aug 14, 2013
- Abate by
- Aug 26, 2013
- Penalty
- Initial $2,200 · Current $1,650 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): A required exit(s), way of approach thereto, and/or way of travel from the exit into the street or open space, was not continuously maintained free of all obstructions or impediments to full instant use in the case of fire or other Warehouse Floor: On May 8, 2013, the exit door facing Northwest exiting into the maintenance area was blocked by the oxygen and acetylene torch kit.
Recent events (2)
- — I (S) $1650
- — Z (S) $2200
1910.106 D02 I
- Issued
- Aug 14, 2013
- Abate by
- Aug 26, 2013
- Penalty
- Initial $2,200 · Current $1,650 Reduced
General-duty citation text
29 CFR 1910.106(d)(2)(i): A flammable liquid was not stored in an approved containers. Warehouse Floor: On May 8, 2013, the 5 Gallon Rodda Paint Brand Lacquer Thinner containers were not stored in a fire resistant storage cabinet.
Recent events (2)
- — I (S) $1650
- — Z (S) $2200
1910.178 M05 III
- Issued
- Aug 14, 2013
- Abate by
- Aug 26, 2013
- Penalty
- Initial $1,320 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(m)(5)(iii): Powered industrial truck(s), with the operator dismounted and within 25 feet of the truck still in his view, did not have the load fully lowered. Warehouse Floor: On May 8, 2013, the load on the Toyota Electric Forklift Truck was left suspended while the operator was not on the forklift.
Recent events (2)
- — I (O) $0
- — Z (S) $1320
1910.253 B04 III
- Issued
- Aug 14, 2013
- Abate by
- Aug 26, 2013
- Penalty
- Initial $2,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS) Warehouse Floor: On May 8, 2013, the Oxygen and Acetylene tanks were not separated and were being stored near the North West exit door.
Recent events (2)
- — I (S) $0
- — Z (S) $2200
1910.305 G01 IV A
- Issued
- Aug 14, 2013
- Abate by
- Aug 26, 2013
- Penalty
- Initial $1,760 · Current $1,320 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Warehouse floor, above Rodda color pallette display and coffee maker: There were multiple flexible cords energizing the display, coffee maker and ceiling lights. b) Warehouse paint mixing room: There were multiple flexible cords energizing the lights in the paint mixing room.
Recent events (2)
- — I (S) $1320
- — Z (S) $1760
1910.305 G02 III
- Issued
- Aug 14, 2013
- Abate by
- Aug 26, 2013
- Penalty
- Initial $3,080 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Warehouse Floor: On May 8, 2013, there was no strain relief on the Anderson Power Products forklift charger plug used for charging the electric forklift, exposing the employee to the potential of electric shock during connecting and disconnecting of the plug.
Recent events (2)
- — I (S) $0
- — Z (S) $3080
1910.157 E02
- Issued
- Aug 14, 2013
- Abate by
- Aug 26, 2013
- Penalty
- Initial $4,400 · Current $3,300 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly. Warehouse Floor: On May 8, 2013, the fire extinguisher located near the exit door facing Northwest was not subjected to a monthly visual inspection and was discharged. CONWOOD PRODUCTS INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313238586 , CITATION NUMBER 01, ITEM NUMBER 2A, ISSUED ON AUGUST 20, 2009, AND CONFIRMED AS A FINAL ORDER ON SEPTEMBER 17, 2009, WITH RESPECT TO A WORKPLACE LOCATED AT LOT #52236 NEW, BARRIGADA, GU 96913.
Recent events (2)
- — I (R) $3300
- — Z (R) $4400
More inspections at Conwood Products, INC.
View Conwood Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 444190)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339052748.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.