Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: UNITED REFINING COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of UNITED REFINING COMPANY in 15 BRADLEY STREET, WARREN, PA 16365 (NAICS 324110). OSHA activity number 339119729.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Refining Company for free Get an email when a new federal OSHA severe-injury report for United Refining Company is published. One employer, no account, unsubscribe in one click.
Site address
15 BRADLEY STREET
City
WARREN
State
PA
ZIP
16365
Mailing
P.O. BOX 780, WARREN, PA 16365
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324110
Employees
426
Ownership type
Private (A)

2 citations on file for this inspection.

1910.23 A02

Serious Gravity 5 15 instances 50 exposed
Issued
Dec 11, 2013
Abate by
Jan 30, 2015
Penalty
Initial $3,400 · Current $1,700 Reduced
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening:     a) United Refining Co / 2000 Pennsylvania Ave, Warren, PA: On or about June 14, 2013 throughout the facility, including, but not limited to the fractionator, Passage openings from fixed ladders to the platforms were not equipped with swinging gate and/or other devices to prevent personnel from falling through the fixed ladder access opening.
Recent events (2)
  • · I (S) $1700
  • · Z (S) $3400

1910.119 J05

Serious Gravity 5 1 instance 20 exposed
Issued
Dec 11, 2013
Abate by
Apr 8, 2014
Penalty
Initial $4,250 · Current $2,500 Reduced
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits:    a) United Refining Co / 2000 Pennsylvania Ave, Warren, PA: On or about June 14, 2013 and at times prior thereto, the diesel engines on the cooling towers were not maintained according to the manufacturer's original design in that the diesel engines were origninally manufactured with over speed protection which had been removed.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $4250

View United Refining Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339119729.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.