Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BEAVER VALLEY ALLOY FOUNDRY COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BEAVER VALLEY ALLOY FOUNDRY COMPANY in 4165 BRODHEAD ROAD, MONACA, PA 15061 (NAICS 331513). OSHA activity number 339173114.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Beaver Valley Alloy Foundry Company — free Get an email when a new federal OSHA severe-injury report for Beaver Valley Alloy Foundry Company is published. One employer, no account, unsubscribe in one click.
Site address
4165 BRODHEAD ROAD
City
MONACA
State
PA
ZIP
15061
Mailing
4165 BRODHEAD ROAD, MONACA, PA 15061
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331513
Employees
42
Ownership type
A

6 citations on file for this inspection.

1910.101 B

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 21, 2013
Abate by
Sep 3, 2013
Penalty
Initial $2,100 · Current $1,364 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:     (a) Core Making Area, CO2 Cylinder: On or before July 10, 2013, employees were exposed to struck-by hazards in that the cylinder was not secured against movement.
Recent events (2)
  • — I (S) $1364
  • — Z (S) $2100

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 21, 2013
Abate by
Oct 8, 2013
Penalty
Initial $2,800 · Current $1,820 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     (a) Core Making Area, Hobart Mixer: On or before July 10, 2013, an employee was exposed to struck-by and/or caught on hazards in that a mixing paddle was not guarded.
Recent events (2)
  • — I (S) $1820
  • — Z (S) $2800

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 21, 2013
Abate by
Oct 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:   (a) Core Making Area, Hobart Mixer: On or before July 10, 2013, an employee was exposed to struck-by hazards in that the mixer was not secured in place.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 21, 2013
Abate by
Oct 18, 2013
Penalty
Initial $2,800 · Current $1,820 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:     (a) Facility: On or before July 10, 2013, employees who conduct electrical maintenance and/or make repairs were not given training on electrical safety related work practices. Employees were not aware that personal protective equipment (PPE) needed to be worn while performing circuit testing.
Recent events (2)
  • — I (S) $1820
  • — Z (S) $2800

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 21, 2013
Abate by
Oct 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with or did not use electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:     (a) Facility: On or before July 10, 2013, employees who conduct electrical maintenance and/or make repairs were not given electrically rated gloves or face shield for conducting testing on circuits.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Aug 21, 2013
Abate by
Oct 31, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:     (a) Facility: On or before July 10, 2013, the employer did not ensure an annual inspection was completed on employees that implement energy isolation procedures.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Beaver Valley Alloy Foundry Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339173114.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.