On , OSHA opened a complaint safety inspection of TIFTON ALUMINUM EXTRUSIONS, INC. in 250 SOUTHWELL BLVD, TIFTON, GA 31794 (NAICS 331319). OSHA activity number 339333437.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIFTON ALUMINUM EXTRUSIONS, INC.
- Site address
- 250 SOUTHWELL BLVD
- City
- TIFTON
- State
- GA
- ZIP
- 31794
- Mailing
- 250 SOUTHWELL BLVD, TIFTON, GA 31794
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331319
- Employees
- 120
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and struck by hazards. a) Extrusion Department, #3 Press, on or about and at times prior to August 21, 2013, the employer did not ensure that hooks used to lift materials were in safe operational condition in that hook latches were damaged or missing, which exposed employees to crushing and struck by hazards. b) Extrusion Department, #2 Press, on or about and at times prior to August 21, 2013, the employer did not ensure that hooks used to lift materials were in safe operational condition in that hook latches were damaged or missing, which exposed employees to crushing and struck by hazards. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
- — Z (S) $4500
1910.37 B02
- Issued
- Feb 14, 2014
- Penalty
- Initial $3,600 · Current $3,600
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Wet Paint Department on or about August 21, 2013, the exit door leading from the painting area was not marked EXIT, exposing employees to burns and smoke inhalation hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
- — Z (S) $3600
1910.107 E02
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $3,600 · Current $3,600
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift. a) Wet Spray painting operation area on or about January 9, 2014, eight 55-gallon drums of paint and seventeen 55-gallon drums of chemical for the dip tank were stored inside the spray painting operation area, exposing employees to fire hazards. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (S) $3600
1910.146 C02
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: a) Extrusion Department, #1 Press Reservoir - on or about August 21, 2013, the employer did not have a sign stating, DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or by another equally effective means, exposing employees to hazardous atmosphere. b) Extrusion Department, #4 Press Reservoir - on or about August 21, 2013, the employer did not have a sign stating, DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or by another equally effective means, exposing employees to hazardous atmosphere. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (S) $4500
1910.147 C04 I
- Issued
- Feb 14, 2014
- Abate by
- Mar 20, 2014
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Extrusion Department - on or about August 21, 2013, and at times prior to, the employer did not develop, document and utilize specific energy control procedures for equipment such as the head saw, trim saw, conveyor systems, the chipper, the peelers, and powered industrial trucks, exposing employees to crush-by and caught-in hazards. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED
Recent events (1)
- — Z (S) $6300
1910.147 C07 I
- Issued
- Feb 14, 2014
- Abate by
- Mar 20, 2014
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) Extrusion Department - on or about August 21, 2013, and at times prior too, training was not provided for employees to ensure they understood the purpose and function of the lockout program and that they acquired the knowledge and skills required for safe application, usage and removal of energy controls, exposing employees to amputation hazards. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED
Recent events (1)
- — Z (S) $6300
1910.157 C01
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $2,700 · Current $2,700
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Extrusion Department, #3 Press on or about August 21, 2013, three portable fire extinguishers were not mounted, exposing employees to burn hazards. b) Extrusion Department, #4 Press on or about August 21, 2013, two portable fire extinguishers were not mounted, exposing employees to burn hazards. c) Extrusion Department, #1 Press on or about August 21, 2013, four portable fire extinguishers were not mounted, exposing employees to burn hazards. d) Wet paint Shop on or about August 21, 2013, the portable fire extinguisher was not mounted, exposing employees to burn hazards. e) Extrusion Department, #2 Press on or about August 21, 2013, two portable fire extinguishers were not mounted, exposing employees to burn hazards. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (S) $2700
1910.178 P01
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $3,600 · Current $3,600
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a) Throughout the plant, on or about August 21, 2013 and at times prior to, employees were exposed to a hazard of being struck by powered industrial trucks (PITs) that were used during night operations, which did not have functional headlights. 1) a Crown forklift 2) Hyster forklift #50 3) Taylor forklift #2 4) Taylor forklift #7 ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (S) $3600
1910.305 B01
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $3,600 · Current $3,600
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Extrusion Department, #2 Press on or about August 21, 2013, two 480-volt electrical control panel boxes had opening due to missing switches on the front cover, exposing employees to electrical shock hazards. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (S) $3600
1910.305 B02
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) Paint Department on or about August 21, 2013, the front cover was partially open on the 480-volt electrical junction box that runs the mixer, exposing employees to electrical hazards. b) Extrusion Department, #3 Press on or about August 21, 2013, the front cover was missing from the 120-volt electrical panel box that energizes the hydraulic unit, exposing employees to electrical hazards. c) Extrusion Department, #3 Press on or about August 21, 2013, the front cover was missing from the 120-vols electrical junction box to the directional control valve, exposing employees to electrical hazards. d) Extrusion Department, #4 Press on or about August 21, 2013, the front cover was partially off from the 120-volt electrical junction box, exposing employees to electrical hazards. e) Extrusion Department, #1 Press on or about August 21, 2013, the front cover was missing from the 120-volt electrical outlet box, exposing employees to electrical hazards. f) Extrusion Department, #1 Press on or about August 21, 2013, the front cover was missing from the 480-volt electrical junction box that runs the sensor unit, exposing employees to electrical hazards. g) Shipping and Receiving on or about August 21, 2013, the front cover was missing from the 120-volt electrical outlet box, exposing employees to electrical hazards. h) Extrusion Department, #2 Press on or about August 21, 2013, the front cover was partially off from two 120-volt electrical junction boxes that run the die slide, exposing employees to electrical hazards. i) Extrusion Department, #2 Press on or about August 21, 2013, the front cover was missing from the 280-volt electrical junction box that runs the log table, exposing employees to electrical hazards. j) Extrusion Department, #2 Press on or about August 21, 2013, the front cover was missing from the 280-volt electrical junction box that runs the furnace, exposing employees to electrical hazards. k) Extrusion Department, #2 Press on or about August 21, 2013, the front cover was partially open on three 480-volt disconnect panel doors, exposing employees to electrical hazards. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED
Recent events (1)
- — Z (S) $6300
1910.305 G02 III
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $3,600 · Current $3,600
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Extrusion Department, #3 Press on or about August 21, 2013, the outer jacket on the 120-volt power cord connected to the directional control valve was withdrawn, exposing the inner conductors and terminals to strain. b) Extrusion Department, #3 Press on or about August 21, 2013, the outer jacket on the 120-volt power cord connected to a sensor unit was withdrawn, exposing the inner conductors and terminals to strain. c) Extrusion Department, #4 Press on or about August 21, 2013, the outer jacket on the end of the 120-volts electrical power cord connected to the gas shutoff valve that runs zone 1 was withdrawn, exposing the inner conductors and terminals to strain. d) Extrusion Department, #4 Press on or about August 21, 2013, the outer jacket on the 480-volt power cord connected to the control panel box that runs the log shear was withdrawn, exposing the inner conductors and terminals to strain. e) Extrusion Department, #1 Press on or about August 21, 2013, the outer jacket on the 480-volt power cord connected to the junction box that runs the sensor unit to the furnace was withdrawn, exposing the inner conductors and terminals to strain. ABATEMENT CERTIFICATION IS NOT REQUIRED
Recent events (1)
- — Z (S) $3600
1910.303 B07
- Issued
- Feb 14, 2014
- Abate by
- Mar 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7): Mechanical execution of work. Electric equipment shall be installed in a neat and workmanlike manner: a) Wet Paint area - on or about and at times prior to January 09, 2014, the employer did not ensure electric wires and surface mounted equipment such as a disconnect panel box were installed in a neat and workmanlike manner. The disconnect panel box was removed and the electrical wires were left hanging down with caps on the ends, exposing employees to an electrical hazard. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (1)
- — Z (O) $0
More inspections at Tifton Aluminum Extrusions, INC.
View Tifton Aluminum Extrusions, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331319)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339333437.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.