OSHA Inspection: TIFTON ALUMINUM EXTRUSIONS, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of TIFTON ALUMINUM EXTRUSIONS, INC. in 250 SOUTHWELL BLVD, TIFTON, GA 31794 (NAICS 331319). OSHA activity number 341207983.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tifton Aluminum Extrusions, INC. — free Get an email when a new federal OSHA severe-injury report for Tifton Aluminum Extrusions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
250 SOUTHWELL BLVD
City
TIFTON
State
GA
ZIP
31794
Mailing
PO BOX 7550, TIFTON, GA 31793
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331319
Employees
40
Ownership type
A

5 citations on file for this inspection.

1910.138 A

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 26, 2016
Penalty
Initial $2,310 · Current $1,386 Reduced
29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees hands were exposed to hazardous condition:  (a) Spray paint area, on or about 01-27-2016, an employee was observed cleaning the air exhaust system without chemical resistant gloves, with hands exposed to contact with "Titan Coatings-Patio White" paint, resulting in potential skin sensitation.
Recent events (2)
  • — I (S) $1386
  • — Z (S) $2310

1910.304 G05

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 26, 2016
Penalty
Initial $2,310 · Current $1,386 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) Press area, on or about 01-27-2016, an "Dayton" electrical fan with damaged cord was found to lack an effective grounding, exposing employees to electrical shock.
Recent events (2)
  • — I (S) $1386
  • — Z (S) $2310

1910.334 A02 I

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 26, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  (a) Press area, on or about 01-27-2016, the employer failed to ensure that plug and cord equipment such as a "Dayton" electrical fan with a broken outer jacket were visually inspected for defects and damage, exposing the employees to electrical shiock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 26, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  (a) Press area, on or about 01-27-2016, the employer failed to remove from service an electrical fan with a damaged cord's outer jacket, exposing the employees to an electric shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 E01

Other-than-serious 4 instances 8 exposed
Issued
Feb 26, 2016
Abate by
Mar 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:  (a) Press area, on or about 01-27-2016, two-leg chain slings used to lift dies did not have identification tag.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Tifton Aluminum Extrusions, INC.'s full OSHA safety record →