Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MADEIRA FRAMING CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MADEIRA FRAMING CO. in 126 HIGH BARNER ROAD HIGHROSE RIDGE, MIDDLETOWN, NY 10940 (NAICS 238130). OSHA activity number 339453698.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Madeira Framing CO. — free Get an email when a new federal OSHA severe-injury report for Madeira Framing CO. is published. One employer, no account, unsubscribe in one click.
Establishment
MADEIRA FRAMING CO.
Site address
126 HIGH BARNER ROAD HIGHROSE RIDGE
City
MIDDLETOWN
State
NY
ZIP
10940
Mailing
34-36 TAPPAN STREET, EAST NEWARK, NJ 07029
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
11
Ownership type
A

16 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Abate by
Feb 28, 2014
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    (a) Second Story Floor - on or about October 31, 2013 - the employer did not establish safety programs for the employees on this site for the hazards that are involved in this line of work.  No inspections of the site have been made by a competent person to identify these hazards.  Employees were exposed to electrical hazards from damaged equipment, struck-by hazards from a lack of personal protective helmets and fall hazards from second story and scaffold surfaces.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1926.21 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Abate by
Feb 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2):  The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    (a) Second Story Floor - on or about October 31, 2013 - the employer did not instruct employees on this site that were performing wood framing installations on the hazards that are involved in this line of work.  Employees were exposed to electrical hazards from damaged equipment, struck-by hazards from a lack of personal protective helmets and fall hazards from second story and scaffold surfaces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 17, 2014
Abate by
Jan 24, 2014
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1926.100(a):  Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    (a) Jobsite - on or about October 31, 2013 - ground laborer employees were not wearing hard hats.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.451 F07

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(f)(7):  Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:    (a) Front of the Building- on or about October 31, 2013 - the field-fabricated scaffold system was not erected by a scaffold competent person.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.451 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(a)(1):  Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it:  (a) Front of the Building- on or about October 31, 2013 - no engineering data was available to substantiate the load-bearing capabilities of the field fabricated scaffold system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(2):  Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide:  (a) Front of the Building- on or about October 31, 2013 - the scaffold deck that was used for wood framed installations was only 8 inches wide.  Scaffold deck elevation was approximately 5 feet, 4 inches from the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2):  Supported scaffold poles, legs, posts, frames or uprights did not bear on base plates, mud sills or other adequate firm foundation:  (a) Front of the Building- on or about October 31, 2013 - the center vertical upright support for the scaffold system did not bear on a mud sill or any other means of an adequate firm foundation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used:  (a) Front of the Building- on or about October 31, 2013 - no proper means of egress was provided for the scaffold system.  Scaffold elevation was approximately 5 feet, 4 inches from the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Abate by
Jan 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a):  The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  (a) Front of the Building- on or about October 31, 2013 - the employer did not provide training to the employee that was performing framing installations from a field-fabricated scaffold system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Abate by
Jan 24, 2014
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     (a) Second Story Floor - on or about October 31, 2013 - no fall protection was available for the employees that were installing framing lumber.  Second story elevation was approximately 13 feet 5 inches to the ground.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Abate by
Feb 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:     (a) Second Story Floor - on or about October 31, 2013 - the employer did not provide a training program to the employees that were performing wood framed installations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1051 A

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Abate by
Jan 24, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.1051(a):  Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:    (a) Second Story Floor - on or about October 31, 2013 - no ladder or stairway was provided for the employees that were performing wood framing installations on the second story floor.  Employees were climbing the diagonal interior wall bracing to access the upper work area.  Second story elevation was approximately 13 feet 5 inches to the ground.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.1060 A

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 17, 2014
Abate by
Feb 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a):  The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:    (a) Second Story Floor - on or about October 31, 2013 - the employer did not provide a training program pursuant to this subpart for the employees that were performing wood framing installations.  Second story elevation was approximately 13 feet 5 inches to the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.50 D01

Other-than-serious 1 instance 4 exposed
Issued
Jan 17, 2014
Abate by
Jan 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.50(d)(1):  First-aid supplies were not easily accessible when required:    (a) Jobsite - on or about October 31, 2013 - first aid supplies were not available on site.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Jan 17, 2014
Abate by
Jan 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a) Jobsite - on or about October 31, 2013 - electric tools; Milwaukee Sawzall model# 6520-2, and the Makita Circular Saw model# 5007F, were not provided with a continual path to ground.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.416 E01

Other-than-serious 1 instance 2 exposed
Issued
Jan 17, 2014
Abate by
Jan 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a) Jobsite - on or about October 31, 2013 - Milwaukee Sawzall, model# 6520-2, serial# B020612030290; Makita Circular Saw, model# 5007F, no serial number, had frayed electrical cords.  The outer insulation of these cords were damaged.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Madeira Framing CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339453698.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.