BARRIGADA, GU —
OSHA Inspection: HG NORTHEAST, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HG NORTHEAST, INC. in NEW RESIDENTIAL SINGLE FAMILY HOUSE LOT 2359-4-R1-NEW-R3, BARRIGADA, GU 96913 (NAICS 236117). OSHA activity number 339465049.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HG NORTHEAST, INC.
- Site address
- NEW RESIDENTIAL SINGLE FAMILY HOUSE LOT 2359-4-R1-NEW-R3
- City
- BARRIGADA
- State
- GU
- ZIP
- 96913
- Mailing
- PO BOX 315962, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236117
- Employees
- 2
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.95 A
- Issued
- Dec 5, 2013
- Abate by
- Dec 27, 2013
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. At the project on November 6, 2013, protective gloves with nitrile or butyl was not used when mixing and applying Custom Blend Standard Thin-Set Mortar.
Recent events (2)
- — I (S) $810
- — Z (S) $1080
1926.102 A01
- Issued
- Dec 5, 2013
- Abate by
- Dec 27, 2013
- Penalty
- Initial $1,080 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. At the front of the project site on November 6, 2013, an employee was not provided with eye and face protection equipment while mixing and applying Custom Blend Standard Thin-Set Mortar.
Recent events (2)
- — I (S) $0
- — Z (S) $1080
1926.300 B01
- Issued
- Dec 5, 2013
- Abate by
- Dec 27, 2013
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: At the project site living room area on November 6, 2013, the Makita GA4030 4-Inch Angle Grinder, Serial Number 791554, designed to accommodate a wheel guard was unguarded. The grinder was used to cut floor tiles.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1926.403 B02
- Issued
- Dec 5, 2013
- Abate by
- Dec 27, 2013
- Penalty
- Initial $1,440 · Current $990 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: At the project site on November 6, 2013, an electrical box with a 110 VAC receptacle, was used as part of an extension cord. The box with receptacle is designed to be installed/mounted in or on a wall.
Recent events (2)
- — I (S) $990
- — Z (S) $1440
1926.405 B02
- Issued
- Dec 5, 2013
- Abate by
- Dec 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: At the project site on November 6, 2013, there was no cover plate on the junction box that contained a 110 V recepticle, that was used to supply power to an extension cord for a 110 VAC Rigdid 1/2 inch drill, Serial Number CS13102DC74027.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Dec 5, 2013
- Abate by
- Dec 19, 2013
- Penalty
- Initial $1,080 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: At the project site on November 6, 2013, the outer insulation of a orange, 50 foot extension cord, was not secured to the plug. The cord supplied power to a 110 VAC Rigdid 1/2 inch drill, Serial Number CS13102DC74027.
Recent events (2)
- — I (S) $0
- — Z (S) $1080
1926.404 B01 I
- Issued
- Dec 5, 2013
- Abate by
- Dec 27, 2013
- Penalty
- Initial $1,080 · Current $810 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. At the project site on November 6, 2013, there was no ground-fault circuit-interrupter protection or an assured equipment grounding conductor program when extension cords were used to power a 110 VAC Rigdid 1/2 inch drill, Serial Number CS13102DC74027. The drill was used to mix Custom Blend Standard Thin-Set Mortar.
Recent events (2)
- — I (S) $810
- — Z (S) $1080
More inspections at HG Northeast, INC.
View HG Northeast, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236117)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339465049.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.