CHALAN PAGO, GU —
OSHA Inspection: HG NORTHEAST, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HG NORTHEAST, INC. in NEW 3 BEDROOM, 3 BATHROOM, 2 CAR GARAGE RESIDENCE MAIMAI ROAD, CHALAN PAGO, GU 96910 (NAICS 236117). OSHA activity number 339482663.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HG NORTHEAST, INC.
- Site address
- NEW 3 BEDROOM, 3 BATHROOM, 2 CAR GARAGE RESIDENCE MAIMAI ROAD
- City
- CHALAN PAGO
- State
- GU
- ZIP
- 96910
- Mailing
- PO BOX 315962, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236117
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.20 B02
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer failed to initiate and maintain programs that provided for frequent and regular inspections of the job sites, materials, and equipment were made by competent persons designated by the employer: At the project on or about November 14, 2013, and at times prior thereto, inspections were not completed to ensure compliance with OSHA regulations or the person that completed the inspections was not competent as there were electrical hazards, unguarded rebars onsite, no toilets onsite, and inadequate housekeeping onsite.
Recent events (2)
- — I (O) $0
- — Z (S) $1020
1926.25 A
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, were not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: At the project on or about November 14, 2013, conduit, scrap rebar pieces, plastic straps and tarps were not kept clear of doorways and passageways.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1926.51 C01
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.51(c)(1): Toilets were not provided for employees: At the project on or about November 14, 2013, and at times prior thereto, there were no toilets onsite. Employees did not travel from site to site during the day. They stayed onsite for the duration of the work shift. Employees said they were not allowed to use the toilet at the house next door and needed to relieve themselves outside.
Recent events (2)
- — I (O) $0
- — Z (S) $1020
1926.403 B02
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: At the project on or about November 14, 2013, an electrical box was not used as designed as it lay on the floor instead of being secured on a surface. The box contained a 110 VAC electrical outlet that supplied power to a 110 VAC Makita circular saw, model number 5007N.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1926.404 B01 I
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: At the project on or about November 14, 2013, there was no assured equipment grounding conductor program or ground fault circuit interrupters to protect employees that used a 110 VAC Makita circular saw, model number 5007N.
Recent events (2)
- — I (S) $0
- — Z (S) $1020
1926.405 B02
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers. When metal covers are used, they were not grounded. In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass were not provided with bushings designed for the purpose or they did not have smooth, well-rounded surfaces on which the cords may bear: At the project on or about November 14, 2013, there was no cover plate for a receptacle in a junction box that lay on the floor. The receptacle provided power to a 110 VAC Makita circular saw, model number 5007N.
Recent events (2)
- — I (S) $0
- — Z (S) $1020
1926.405 G02 IV
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief was provided which will prevent pull from being directly transmitted to joints or terminal screws: At the project on or about November 14, 2013, there was no strain relief for an extension cord that entered an electrical box. The connector on the electrical box was designed to connect PVC electrical conduit to the box, could not be secured to the extension cord, and could not prevent pull on the receptacle terminal screws or joints. The box contained a 110 VAC electrical outlet that supplied power to a 110 VAC Makita circular saw, model number 5007N.
Recent events (2)
- — I (S) $0
- — Z (S) $1020
1926.701 B
- Issued
- Jan 28, 2014
- Abate by
- Feb 5, 2014
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, was not guarded to eliminate the hazard of impalement: At the project on or about November 14, 2013, dozens of rebars were not guarded against impalement. The 3/8s inch diameter rebars protruded vertically about 36 to 40 inches from ground level. The rebars protruded from concrete masonry units on the perimeter of the property. Some rebars onsite were capped.
Recent events (2)
- — I (S) $0
- — Z (S) $1020
More inspections at HG Northeast, INC.
View HG Northeast, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236117)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339482663.