Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RODRIGUEZ ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RODRIGUEZ ROOFING in 14556 HUNTERS GROVE, EL PASO, TX 79938 (NAICS 238160). OSHA activity number 339511982.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rodriguez Roofing — free Get an email when a new federal OSHA severe-injury report for Rodriguez Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
RODRIGUEZ ROOFING
Site address
14556 HUNTERS GROVE
City
EL PASO
State
TX
ZIP
79938
Mailing
12200 BRANELL LN, EL PASO, TX 79928
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Repeat Gravity 5 1 instance 2 exposed
Issued
Jan 23, 2014
Abate by
Mar 31, 2014
Penalty
Initial $11,000 · Current $7,200 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:    On or about December 05, 2013, and at times prior thereto, employees were working on the roof of a residential building without appropriate fall protection. Employees were exposed to potential fall hazards of 6 feet or more to the ground below.    Rodriguez Roofing was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 313499048, citation number 1, item number 1 and was affirmed as a final order on February 18, 2011, with respect to a workplace located at 12557 Wolf Berry, El Paso, TX 79938.      Rodriguez Roofing was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 313498347, citation number 2, item number 1 and was affirmed as a final order on October 05, 2010, with respect to a workplace located at 12139 Northview Dr., El Paso, TX 79934.
Recent events (2)
  • — I (R) $7200
  • — Z (R) $11000

1926.405 G02 IV

Other-than-serious 1 instance 3 exposed
Issued
Jan 23, 2014
Abate by
Feb 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  On or about December 05, 2013, and at times prior thereto, employees were working on a residential building, using an air compressor which had a damaged strain relief. This exposed employees to potential electrical hazards.