OSHA Inspection: TRUSS COMPONENTS OF ATLANTA, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of TRUSS COMPONENTS OF ATLANTA, INC. in 2445 OLD COVINGTON HWY SW, CONYERS, GA 30012 (NAICS 321214). OSHA activity number 339602880.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Truss Components of Atlanta, INC. for free Get an email when a new federal OSHA severe-injury report for Truss Components of Atlanta, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2445 OLD COVINGTON HWY SW
City
CONYERS
State
GA
ZIP
30012
Mailing
2445 OLD COVINGTON HWY SW, CONYERS, GA 30012
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321214
Employees
29
Ownership type
A

4 citations on file for this inspection.

1910.95 K01

Repeat Gravity 5 2 instances 10 exposed
Issued
Aug 27, 2014
Abate by
Oct 10, 2014
Penalty
Initial $7,700 · Current $7,700

Hazardous substances 81108111

29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k). The employer did not institute a training program and ensure employee participation in the program:  On or about March 26, 2014:  a)  Truss Components of Atlanta, Inc., Conyers, GA - In the production area, an employee operating the web saw was exposed to a noise time-weighted average (TWA) of 91.2 dBA, exceeding the action level of 85 dBA.  The exposure was obtained from a sample taken over 474 minutes.  Zero exposure was assumed for the unsampled period of six minutes.  A training program was not established.   b)  Truss Components of Atlanta, Inc., Conyers, GA - In the production area, an employee building floor trusses was exposed to a projected noise time-weighted average (PTWA) of 90.0 dBA, exceeding the action level of 85 dBA.  The exposure was obtained from a sample taken over 474 minutes.  Zero exposure was assumed for the unsampled period of six minutes. A training program was not established.  Truss Components of Atlanta, Inc., Conyers, GA - In the production area, an employee catching wood from the chord saw was exposed to a projected noise time-weighted average (PTWA) of 88.6 dBA, exceeding the action level of 85 dBA.  The exposure was obtained from a sample taken over 476 minutes.  Zero exposure was assumed for the unsampled period of four minutes.  A training program was not established.  Truss Components of Atlanta, Inc., Conyers, GA - In the production area, an employee building roof trusses was exposed to a projected noise time-weighted average (PTWA) of 88.8 dBA, exceeding the action level of 85 dBA.  The exposure was obtained from a sample taken over 469 minutes.  Zero exposure was assumed for the unsampled period of 11 minutes.  A training program was not established.  Truss Components of Atlanta, Inc., Conyers, GA - In the production area, an employee operating the chord saw was exposed to a projected noise time-weighted average (PTWA) of 89.0 dBA, exceeding the action level of 85 dBA.  The exposure was obtained from a sample taken over 464 minutes.  Zero exposure was assumed for the unsampled period of 16 minutes.  A training program was not established.  Truss Components of Atlanta, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.95(k)(1), which was contained in OSHA inspection number 935584, citation number 1, item number 1c and was affirmed as a final order on December 9, 2013, with respect to a workplace located at 2445 Old Covington Hwy SW, Conyers, GA 30012.
Recent events (1)
  • · Z (R) $7700

1910.213 S06

Repeat Gravity 5 1 instance 2 exposed
Issued
Aug 27, 2014
Penalty
Initial $7,700 · Current $7,700
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:  On or about February 27, 2014:  Employees in the main production area using the Dewalt saw were exposed to fire hazards due to the accumulation of dust that was classified as a Class II dust.    Truss Components of Atlanta, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(s)(6), which was contained in OSHA inspection number 935584, citation number 1, item number 3 and was affirmed as a final order on December 9, 2013, with respect to a workplace located at 2445 Old Covington Hwy SW, Conyers, GA 30012.
Recent events (1)
  • · Z (R) $7700

1910.1200 E01

Repeat Gravity 5 1 instance 2 exposed
Issued
Aug 27, 2014
Abate by
Oct 10, 2014
Penalty
Initial $6,160 · Current $6,160
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:(a  On or about February 27, 2014:  Employees in the production areas were exposed to wood dust, diesel and gas, oil, and fumes from welding during repairs. A written hazard communication program was not established and implemented.  Truss Components of Atlanta, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(e)(1), which was contained in OSHA inspection number 935584, citation number 1 item number 4a, and was affirmed as a final order on December 9, 2013, with respect to a workplace located at 2445 Old Covington Hwy SW, Conyers, GA 30012.
Recent events (1)
  • · Z (R) $6160

1910.1200 H01

Repeat Gravity 5 1 instance 10 exposed
Issued
Aug 27, 2014
Abate by
Oct 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about February 27, 2014:  Employees in the production areas were exposed to wood dust, diesel and gas, oil, and fumes from welding during repairs. Employees had not been provided effective information and training on the hazards of wood dust and other chemicals used in the facility.  Truss Components of Atlanta, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(h)(1), which was contained in OSHA inspection number 935584, citation number 1 item number 4a, and was affirmed as a final order on December 9, 2013, with respect to a workplace located at 2445 Old Covington Hwy SW, Conyers, GA 30012.
Recent events (1)
  • · Z (R) $0

View Truss Components of Atlanta, INC.'s full OSHA safety record →