PECOS, TX —
OSHA Inspection: STALLION OIL FIELD SERVICES, LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STALLION OIL FIELD SERVICES, LTD. in RIG #143, BLACKJACK 16 LEASE, WELL #3H, PECOS, TX 79772 (NAICS 213112). OSHA activity number 339607087.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STALLION OIL FIELD SERVICES, LTD.
- Site address
- RIG #143, BLACKJACK 16 LEASE, WELL #3H
- City
- PECOS
- State
- TX
- ZIP
- 79772
- Mailing
- 950 CORBINDALE, SUITE 300, HOUSTON, TX 77024
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.305 A02 X
- Issued
- May 7, 2014
- Abate by
- May 13, 2014
- Penalty
- Initial $2,550 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage: On or about February 24, 2014, Rig 143, a 240V nominal black electrical cable used to supply power to the Company Man trailer was continuously run over by vehicular traffic and foot traffic and not protected from damage; employees were exposed to electrical shock hazards.
Recent events (2)
- — I (O) $1750
- — Z (S) $2550
1910.305 G02 III
- Issued
- May 7, 2014
- Abate by
- May 13, 2014
- Penalty
- Initial $2,550 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about February 24, 2014, Rig 143, behind Stallion Trailer #39625, the 10-foot 240V nominal electrical cable going into the circuit breaker box had strain relief broken. Employees were exposed to electrical shock hazards.
Recent events (2)
- — I (S) $1750
- — Z (S) $2550
1910.305 B01 I
- Issued
- May 7, 2014
- Abate by
- May 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: On or about February 24, 2014, Rig 143, behind the Directional Drillers Trailer, the 240V circuit breaker box had a knockout pushed in leaving an opening going into the box. Employees were exposed to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Stallion OIL Field Services, LTD.
View Stallion OIL Field Services, LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339607087.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.