Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACME ERECTORS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACME ERECTORS INC. in EAST OF 905 WEST MAIN, MARION, IL 62959 (NAICS 238120). OSHA activity number 339641508.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acme Erectors INC. — free Get an email when a new federal OSHA severe-injury report for Acme Erectors INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ACME ERECTORS INC.
Site address
EAST OF 905 WEST MAIN
City
MARION
State
IL
ZIP
62959
Mailing
9511 WATSON INDUSTRIAL PARK, SAINT LOUIS, MO 63126
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
6
Ownership type
A

1 citation on file for this inspection.

1926.453 B02 V

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 6, 2014
Abate by
Jun 12, 2014
Penalty
Initial $2,678 · Current $1,066 Reduced
29 CFR 1926.453(b)(2)(v):       A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:   Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated:           a)    On the west section of building being constructed, while working in a Genie S-45 aerial lift, employees were exposed to fall hazards of up to 30 feet.  The employees were wearing personal fall protection harnesses but failed to attach their lanyards to the anchor points of the basket   b)    On the west section of building being constructed, while working in a JLG 600S aerial lift, one employee were exposed to fall hazards of up to 30 feet.  The employee was wearing personal fall protection harnesses but failed to attach their lanyard to the anchor points of the basket
Recent events (2)
  • — I (S) $1066
  • — Z (S) $2678

View Acme Erectors INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339641508.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.