PONTIAC, IL ·
OSHA Inspection: INTERLAKE MECALUX, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of INTERLAKE MECALUX, INC. in 701 INTERLAKE DR, PONTIAC, IL 61764 (NAICS 337215). OSHA activity number 339655961.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERLAKE MECALUX, INC.
- Site address
- 701 INTERLAKE DR
- City
- PONTIAC
- State
- IL
- ZIP
- 61764
- Mailing
- 701 INTERLAKE DR, PONTIAC, IL 61764
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337215
- Employees
- 280
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.303 H02 II
- Issued
- Jul 11, 2014
- Penalty
- Initial $4,400 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.303(h)(2)(ii): Electrical installations rated over 600 volts, nominal, that were open to unqualified persons were not made with metal-enclosed equipment or enclosed in a vault or in an area with access controlled by a lock: Employees were exposed to electrical shock because the buildings main power supply and transformer room was not locked to prevent access by unqualified persons.
Recent events (2)
- · I (S) $2200
- · Z (S) $4400
1910.305 B02 I
- Issued
- Jul 11, 2014
- Penalty
- Initial $4,400 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: Employees at roll form machines #1 and #2 were exposed to accidental contact with live electrical conductors because an electrical outlet box was damaged and was not guarded with an approved cover.
Recent events (2)
- · I (S) $2200
- · Z (S) $4400
1910.212 A03 II
- Issued
- Jul 11, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $38,500 · Current $19,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zones during operating cycles: An employee working to form parts on the #2 AccuraPress was exposed to amputation hazards because the employee was not protected from contact with the die and the point of operation was not guarded to prevent employees from reaching into the die during an operating cycle. Interlake Mecalux, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.212(a)(3)(ii), which was contained in OSHA inspection number 92311, citation number 1, item number 3 and was affirmed as a final order on January 3, 2012, with respect to a workplace located at 701 Interlake Drive, Pontiac, IL 61764.
Recent events (2)
- · I (R) $19250
- · Z (R) $38500
1910.1200 F05 I
- Issued
- Jul 11, 2014
- Abate by
- Jul 17, 2014
- Penalty
- Initial $220 · Current $110 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: Employees were exposed to containers containing hazardous substances and those containers were not labeled with the identity of the contexts. The containers were located on the second tier of the warehouse racking near the air compressors. Interlake Mecalux, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(i), which was contained in OSHA inspection number 943084, citation number 2, item number 2 and was affirmed as a final order on February 13, 2014, with respect to a workplace located at 1600 N. 25th Ave, Melrose Park, IL 60161.
Recent events (2)
- · I (R) $110
- · Z (R) $220
1910.1200 F05 II
- Issued
- Jul 11, 2014
- Abate by
- Jul 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: Employees using spray bottles containing Exxon Mobil diesel engine oil were exposed to the hazards associated with the substance and the containers were not labeled with the appropriate hazard warnings. Interlake Mecalux, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(ii), which was contained in OSHA inspection number 943084, citation number 2, item number 3 and was affirmed as a final order on February 13, 2014, with respect to a workplace located at 1600 N. 25th Ave, Melrose Park, IL 60161.
Recent events (2)
- · I (R) $0
- · Z (R) $0
More inspections at Interlake Mecalux, INC.
View Interlake Mecalux, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337215)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339655961.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.