EAGLE, ID ·
OSHA Inspection: G&G GUTTERS AND ROOFS LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of G&G GUTTERS AND ROOFS LLC in 906 E KNOLL DR., EAGLE, ID 83616 (NAICS 238160). OSHA activity number 339677460.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G&G GUTTERS AND ROOFS LLC
- Site address
- 906 E KNOLL DR.
- City
- EAGLE
- State
- ID
- ZIP
- 83616
- Mailing
- 1413 W MEGAN ST, CHANDLER, AZ 85224
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- Jul 29, 2014
- Abate by
- Aug 8, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a) On the roof: An employee was performing roofing activities on a 4:12 to 8:12 residential roof without fall protection systems in place. Employee was exposed to falls ranging from 10 feet to 18.4 feet. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.502 D21
- Issued
- Jul 29, 2014
- Abate by
- Aug 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a) On the roof: Employees were using ropes that had visible damage. Employees were exposed to falls ranging from 10 feet to 18.4 feet. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.503 A02 III
- Issued
- Jul 29, 2014
- Abate by
- Aug 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) On the roof: the employer did not ensure employee understanding and comprehension of fall protection training by employees engaged in residential roofing activities. One employee had the rope grab of his life line at the knotted end after it draped over the eve, touched the ground and returned back to his location on the roof and attached to his lanyard. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B01
- Issued
- Jul 29, 2014
- Abate by
- Aug 4, 2014
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) At the roof: employees used an aluminum extension that extended one rung (approximately one foot) above the eve of the roof. Employee was exposed to falls 9.3 feet. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $1200
- · Z (S) $2400
1926.1053 B05 I
- Issued
- Jul 29, 2014
- Abate by
- Aug 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support: a) At the roof: employees used an aluminum extension ladder that was at an angle of 49 degrees instead of the 75.5 degree angle to access the roof. Note: Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at G&G Gutters and Roofs LLC
View G&G Gutters and Roofs LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339677460.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.