Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: G&G GUTTERS AND ROOFS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of G&G GUTTERS AND ROOFS LLC in 906 E KNOLL DR., EAGLE, ID 83616 (NAICS 238160). OSHA activity number 339677460.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G&G Gutters and Roofs LLC for free Get an email when a new federal OSHA severe-injury report for G&G Gutters and Roofs LLC is published. One employer, no account, unsubscribe in one click.
Site address
906 E KNOLL DR.
City
EAGLE
State
ID
ZIP
83616
Mailing
1413 W MEGAN ST, CHANDLER, AZ 85224
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
Private (A)

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 29, 2014
Abate by
Aug 8, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:  a)     On the roof: An employee was performing roofing activities on a 4:12 to 8:12 residential roof without fall protection systems in place. Employee was exposed to falls ranging from 10 feet to 18.4 feet.  Note: Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.502 D21

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 29, 2014
Abate by
Aug 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:  a)     On the roof:  Employees were using ropes that had visible damage. Employees were exposed to falls ranging from 10 feet to 18.4 feet.  Note: Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.503 A02 III

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 29, 2014
Abate by
Aug 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used:    a)      On the roof:  the employer did not ensure employee understanding and comprehension of fall protection training  by employees engaged in residential roofing activities. One employee  had the rope grab of his life line at the knotted end after it draped over the eve, touched the ground and returned back to his location on the roof and attached to his lanyard.   Note: Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 29, 2014
Abate by
Aug 4, 2014
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a)     At the roof:  employees used an aluminum extension that extended  one rung (approximately one foot) above the eve of the roof. Employee was exposed to falls 9.3 feet.  Note: Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2400

1926.1053 B05 I

Serious Gravity 5 1 instance 8 exposed
Issued
Jul 29, 2014
Abate by
Aug 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support:    a)       At the roof:  employees used an aluminum extension ladder that was at an angle of 49 degrees instead of the 75.5 degree angle to access the roof.    Note: Abatement certification IS required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View G&G Gutters and Roofs LLC's full OSHA safety record →