Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SNOQUALMIE ENTERTAINMENT AUTHORITY DBA SNOQUALMIE CASINO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SNOQUALMIE ENTERTAINMENT AUTHORITY DBA SNOQUALMIE CASINO in 37500 SE NORTH BEND WAY, SNOQUALMIE, WA 98065 (NAICS 713210). OSHA activity number 339749038.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Snoqualmie Entertainment Authority DBA Snoqualmie Casino — free Get an email when a new federal OSHA severe-injury report for Snoqualmie Entertainment Authority DBA Snoqualmie Casino is published. One employer, no account, unsubscribe in one click.
Site address
37500 SE NORTH BEND WAY
City
SNOQUALMIE
State
WA
ZIP
98065
Mailing
37500 SE NORTH BEND WAY, SNOQUALMIE, WA 98065
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713210
Employees
1198
Ownership type
A

6 citations on file for this inspection.

1910.212 B

Serious Gravity 1 1 instance 25 exposed
Issued
May 27, 2014
Abate by
Jul 14, 2014
Penalty
Initial $2,025 · Current $1,400 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:      a) Main Shop, where the Westward drill press was not anchored to a portable base.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2025

1910.253 B02 II

Serious Gravity 1 1 instance 25 exposed
Issued
May 27, 2014
Abate by
Jul 14, 2014
Penalty
Initial $2,025 · Current $1,400 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:      a) Main Shop, where an oxygen and an acetylene cylinder were stored together.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2025

1910.303 B02

Serious Gravity 1 7 instances 25 exposed
Issued
May 27, 2014
Penalty
Initial $1,721 · Current $2,700
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      a)  Facility, where electrical equipment not used as listed or labeled included:    1. Environmental Services Shop, where the Ace relocatable power tap was daisy chained with the orange extension cord and used to supply power to the Hoover Linx cordless battery chargers.    2. Environmental Services Shop, where the Ace relocatable power tap was permanently mounted to the wall and used to supply power to the Service Paper Company battery charger and the Advance Terra 28-B dry vacuum battery charger.     3. Environmental Services Shop, where two relocatable power taps were daisy chained with the yellow extension cord and used to supply power to the Hoover Linx cordless battery chargers and the Magic Chef refrigerator.     4. Environmental Services Repair Shop, where the Ace relocatable power tap was daisy chained with the permanently mounted Ativa relocatable power tap that was daisy chained with the yellow extension cord that was plugged into the three outlet extension cord and used to supply power to the Emerson radio.    5. Environmental Services Repair Shop, where the permanently mounted Belkin relocatable power tap was to supply power to the portable fan and the work bench lamp.    6. Upholstery Shop, where the Isobar relocatable power tap was used to supply power to the Polar Aire portable fan.    7. MIS Server Room, where the Belkin relocatable power tap was daisy chained with the red extension cord and used to supply power to the portable Sharp air conditioner.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $1721

1910.303 G02 I D

Serious Gravity 1 2 instances 7 exposed
Issued
May 27, 2014
Abate by
Jul 14, 2014
Penalty
Initial $2,025 · Current $0 Reduced
29 CFR 1910.303(g)(2)(i)(D): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by  elevation of 2.44 m (8.0 ft) or more above the floor or other working surface:   a) Groundskeeping, where florescent light fixtures equipped with unguarded bulbs included:     1. Storage Box 1, florescent light fixtures measured 6 feet 10 inches above floor level.    2. Storage Box 2, florescent light fixtures measured 6 feet 7 inches above floor level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2025

1910.37 B02

Other-than-serious 3 instances 25 exposed
Issued
May 27, 2014
Abate by
Jul 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a) Facility, where the designated emergency exit doors not equipped with exit signs included:  1. Environmental Services Shop, double doors that opened into the exit access.   2. Carpenter Shop Storage, passageway that opened into the exit access.  3. MIS Server Room, door that opened into the exit access.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.37 B05

Other-than-serious 1 instance 25 exposed
Issued
May 27, 2014
Abate by
Jul 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):   a) Carpenter Repair Shop, where the double doors to the shop were not equipped with signage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Snoqualmie Entertainment Authority DBA Snoqualmie Casino's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339749038.