OSHA Inspection: SUBURBAN PLASTICS COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUBURBAN PLASTICS COMPANY in 1000 ENTERPRISE DR, GRENADA, MS 38901 (NAICS 326199). OSHA activity number 339756363.

Watch Suburban Plastics Company — free Get an email when a new federal OSHA severe-injury report for Suburban Plastics Company is published. One employer, no account, unsubscribe in one click.
Site address
1000 ENTERPRISE DR
City
GRENADA
State
MS
ZIP
38901
Mailing
1000 ENTERPRISE DR, GRENADA, MS 38901
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
238
Ownership type
A

10 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 70 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2040.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  (a) Mold press #1 - On or about May 6, 2014, there was an accumulation of Class II combustible dust on the drill fixture, electrical boxes on the wall, electrical boxes, hydraulic pumps, wall fans, and motors.
Recent events (2)
  • — I (S) $2040
  • — Z (S) $3400

1910.22 A02

Serious Gravity 5 1 instance 70 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  (a) Mold press #1 - On or about May 6, 2014, there was an accumulation of Class II combustible dust on floor under and around the drill fixture.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 75 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2550.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  (a) Throughout the facility - On or about May 6, 2014, specific energy control procedures were not developed for the unexpected release of hazardous energy for equipment such as but not limited to the mold presses, injection molding machines, and air compressors.
Recent events (3)
  • — Z $21000
  • — I (S) $2550
  • — Z (S) $4250

1910.147 C06 I

Serious Gravity 5 1 instance 75 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2550.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Throughout the facility - On or about May 6, 2014, the employer did not conduct any periodic inspection of the energy control procedures to assure that the procedures were still correct and if employees are following the specific procedure.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

1910.242 B

Serious Gravity 1 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1530.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:   (a) Mold press #1 - On or about May 6, 2014, an air nozzle using compressed air for cleaning measured 75 psi.   (b) Mold press #9 - On or about May 6, 2014, an air nozzle using compressed air for cleaning measured 75 psi.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

1910.303 G02 I

Serious Gravity 5 3 instances 9 exposed
Issued
Abate by
Penalty
Initial $4250.00 · Current $2550.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:   (a) Mold press #1 - On or about May 6, 2014, the motor starter for a wall mounted exhaust fan was missing the front cover.  (b) Mold press #4 - On or about April 3, 2014, the door to a electrical control box was not closed.  (c) Quality control table - On or about May 6, 2014, a receptacle above the QC table was missing a cover plate.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

1910.305 B01 I

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2040.00 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:  (a) Mold press #6, next to the break room - On or about May 6, 2014, there were two (2) pairs of receptacle boxes (each pair consisted of two 4 x 4 receptacle boxes). Each pair was hanging loose from the bottom of an electrical cabinet on the back side of the press.  (b) Mold press #6, next to the break room - On or about May 6, 2014, there were two (2) coated flexible conduits (Greenfield) that had came loose from their LB conduit fitting.
Recent events (2)
  • — I (S) $2040
  • — Z (S) $3400

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) Mold press #1 - On or about May 6, 2014, there were unused openings in the top of a control box that were not plugged.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  (a) Mold press #1 - On or about May 6, 2014, a cover plate was missing the 2 x 4 junction box on the drill stand fixture.  (b) Mold press #1 - On or about May 6, 2014, the motor terminal junction box was missing a cover plate on the hydraulic pump.  (c) Mold press #6 (next to the break room) - On or about May 6, 2014, six (6) hydraulic valves were missing the terminal cover plates.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 C02

Serious Gravity 1 1 instance 70 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1530.00 Reduced
29 CFR 1910.307(c)(2): 29 CFR 1910.307(c)(2): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not safe for the hazardous (classified location), nor approved for the hazardous (classified) location or the ignitable or combustible properties of the specific gas, vapor, dust or fiber that was present:  (a) Mold press #1 - On or about May 6, 2014, electrical equipment such as junction boxes, disconnects, electric motors, wall fans, control panels, and motor starters were not approved for the Class II combustible dust environment.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

View SUBURBAN PLASTICS COMPANY's full OSHA safety record →