SAN ANTONIO, TX —
OSHA Inspection: JP STEEL ERECTORS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JP STEEL ERECTORS in 7430 N.W. LOOP 410, SAN ANTONIO, TX 78227 (NAICS 238120). OSHA activity number 339756603.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JP STEEL ERECTORS
- Site address
- 7430 N.W. LOOP 410
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78227
- Mailing
- 4801 COUNTY ROAD 616, ALVARADO, TX 76009
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 A06
- Issued
- May 28, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person and shall be constructed and loaded in accordance with that design: Main building under construction, On or about April 03, 2014, an employee was exposed to a fall hazard greater than 10 feet from a makeshift scaffold being elevated by a Genie Telescopic Forklift, GTH-844, while welding the metal frame of an awning.
Recent events (1)
- — Z (S) $1600
1926.451 C02 IV
- Issued
- May 28, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms without being specifically designed by the manufacturer for such use: Main building under construction, On or about April 03, 2014, an employee was exposed to a fall hazard greater than 10 feet from a makeshift scaffold being elevated by a Genie Telescopic Forklift, GTH-844, while welding the metal frame of an awning.
Recent events (1)
- — Z (S) $1600
1926.451 G01 VII
- Issued
- May 28, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: Main building under construction, Genie Telescopic Forklift, GTH-844, On or about April 03, 2014, an employee without fall protection was exposed to a fall hazard greater than 10 feet from a makeshift scaffold without guardrails, while welding the metal frame of an awning.
Recent events (1)
- — Z (S) $1600
1926.602 C01 VI
- Issued
- May 28, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.602(c)(1)(vi): Industrial truck(s) in use did not meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standards for Powered Industrial Trucks: Main building under construction, GTH-844, On or about April 03, 2014, an employee was operating Genie Telescopic Forklift, GTH-844, to elevate an employee who was working from a makeshift scaffold, welding the metal frame of an awning and left the forklift unattended with the load elevated.
Recent events (1)
- — Z (S) $1600
1926.602 D
- Issued
- May 28, 2014
- Abate by
- Jun 17, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by 1910.178(l) of this chapter: 29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck: Main building under construction, On or about April 03, 2014, an employee was operating Genie Telescopic Forklift, GTH-844, to elevate an employee who was working from a makeshift scaffold, welding the metal frame of an awning, while not being trained and certified by his current employer.
Recent events (1)
- — Z (S) $1600
More inspections at JP Steel Erectors
View JP Steel Erectors's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339756603.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.