OSHA Inspection: DEPT OF THE NAVY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEPT OF THE NAVY in 110 NNPTC CIRCLE NAVAL WEAPONS STATION CHARLESTON, GOOSE CREEK, SC 29445 (NAICS 928110). OSHA activity number 339774036.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dept of the Navy — free Get an email when a new federal OSHA severe-injury report for Dept of the Navy is published. One employer, no account, unsubscribe in one click.
Establishment
DEPT OF THE NAVY
Site address
110 NNPTC CIRCLE NAVAL WEAPONS STATION CHARLESTON
City
GOOSE CREEK
State
SC
ZIP
29445
Mailing
110 NNPTC CIRCLE NAVAL WEAPONS STATION CHARLESTON, GOOSE CREEK, SC 29445
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
198
Ownership type
D

14 citations on file for this inspection.

1910.23 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening:   a) South wall of the Overhead Storage/Attic Area at the center of the CEP Building: There was no chain or other type of similar device at the doorway and entrance to the fixed ladder, to prevent employees from falling 10 feet to the floor below.  ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 C01

Serious Gravity 5 1 instance 20 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.  a) North end of the Loading Dock: Employees working/walking-by the edge of the dock which was not protected by standard railings, were exposed to falls of over 5 feet.  ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A03

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 28, 2014
Abate by
Oct 1, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) South end of the southeast wing of the 3rd floor: A way of exit consisting of a side door and an escape ladder, lead to a ground floor maintenance closet which was subject to locking.   b) East end of the southeast wing of the 3rd floor: A way of exit consisting of a side door and an escape ladder, lead to a ground floor maintenance closet which was subject to locking.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 B03

Serious Gravity 5 3 instances 3 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:  a) CEP Shop: A Ryobi Band Saw model number BS904, Serial Number EM131722210, was not equipped with a magnetic switch or other device that would prevent the saw from restarting when the power was restored after a power failure.  b) CEP Shop: A Ridgid table saw model number 4512, Serial Number EM131640354,was not equipped with a magnetic switch or other device that would prevent the saw from restarting when the power was restored after a power failure.   c) CEP Shop: A Milwaukee router attached to a job made router table, was not equipped with a magnetic switch or other device that would prevent the saw from restarting when the power was restored after a power failure.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  a) CEP Shop: A Ridgid table saw model number 4512, Serial Number EM131640354, used for ripping was not equipped with a blade guard.    ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  a) CEP Shop: A Ridgid table saw model number 4512, Serial Number EM131640354, used for ripping was not equipped with non kickback fingers or dogs.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i:  a) Northwest corner of the Shop Area of the CEP: Employees were using compressed air operating at 70 p.s.i. to clean debris off equipment and other surfaces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) West wall of the CEP Break Room: Two 120 volt relocatable power taps designed and listed to provide power to high concentrations of low powered loads such as computers, TV's radios, printers, etc. were used to provide power for high powered loads including an Emerson Microwave Oven; Applica coffee pot; Delta/Rockwell drill press; They were daisy chained together.   ABATEMENT CERTICIFICATION IS REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served:  a) West wall of the CEP Break Room: A Tripp Lite 120 relocatable power tap with a maximum load rating of 15 amps had appliances with a total amperage of  39.8 amps plugged into it.   ABATEMENT CERTICIATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a) Northwest corner of the CEP Shop: A 120 volt extension cord used to power equipment in the area was not equipped with a ground prong.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   a) West wall of the CEP Break Room: A 120 volt Delta/Rockwell drill press serial number 1596560 was plugged into a relocatable power tap instead of being  plugged directly into a receptacle outlet.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:   a) Northwest corner of the CEP Shop: A 120 volt extension cord used at the site had the outer insulation near the female plug-end pulled back, exposing the individual insulated wires underneath. It was still in service and available for use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.40 A

Other-than-serious 1 instance 198 exposed
Issued
Aug 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.  a) Navel Health Clinic Charleston: On or about 05-15-2014, the employer failed to provide copies of the OSHA-300 injury and illness records to the Safety Compliance Officer within four business hours.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F05 I

Other-than-serious 6 instances 3 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:   a) CEP Outside Chemical Storage Area: Inside of a chemical storage cabinet were four (4) - 5 gallon metal fuel cans and one (1) - 5 gallon plastic fuel can which contained varying levels of gasoline. None of the cans were marked as to their contents.    b) CEP Outside Chemical Storage Area: A chemical storage cabinet containing four (4) - 5 gallon metal fuel cans of diesel did not have a hazardous warning label on the outside door of the cabinet.   ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dept of the Navy's full OSHA safety record →