SAN ANTONIO, TX —
OSHA Inspection: IMPROVED PIPING PRODUCTS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of IMPROVED PIPING PRODUCTS INC in 4311 DIRECTOR DR, SAN ANTONIO, TX 78219 (NAICS 332996). OSHA activity number 339777229.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IMPROVED PIPING PRODUCTS INC
- Site address
- 4311 DIRECTOR DR
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78219
- Mailing
- 4311 DIRECTOR DR, SAN ANTONIO, TX 78219
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 49
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Aug 22, 2014
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides: In the 2nd floor storage/employee break area, Southwest corner of building, on or about May 20, 2014 and at times prior thereto, employees were exposed to a fall hazard greater than 4 feet while walking on the second floor storage/employee break area; from an open passage that had one chain at 23 inches in height to prevent employees from falling.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1910.219 C04 I
- Issued
- Aug 22, 2014
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends did not present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves: In the production area, South, on or about May 20, 2014 and at times prior thereto, employees were exposed to a caught by hazard while using the #2 Bullard 54 inch lathe with an exposed hexagonal bolt that did not have a smooth edge.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.242 B
- Issued
- Aug 22, 2014
- Abate by
- Aug 28, 2014
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air for cleaning purposes was not reduced to less than 30 p.s.i: In the chain saw cutting area, East wall, on or about May 20, 2014 and at times prior thereto, employees were exposed to a struck by hazard by using compressed air greater than 30p.s.i to clean the plastic debris from the chain saw.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.305 B01 II
- Issued
- Aug 22, 2014
- Abate by
- Sep 6, 2014
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed: In the main electrical switchboard area, Northeast corner, on or about May 20, 2014 and at times prior thereto, employees were exposed to an electrical hazard when walking in close proximity to a General Electric Spectra Series Switchboard (2000 Amps, 480Y/277V~) that did not have the cover fully closed.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.22 D01
- Issued
- Aug 22, 2014
- Abate by
- Sep 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent: In the 2nd floor storage/employee break area, Southwest corner of building, on or about May 20, 2014 and at times prior thereto, employees were exposed to a crushed, struck-by hazard while working in offices located under the second floor storage/employee break area that did not have load ratings affixed to the space.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Improved Piping Products INC
View Improved Piping Products INC's full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339777229.