Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IMPROVED PIPING PRODUCTS INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of IMPROVED PIPING PRODUCTS INC. in 4311 DIRECTOR DR, SAN ANTONIO, TX 78219 (NAICS 332996). OSHA activity number 340366285.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Improved Piping Products INC. — free Get an email when a new federal OSHA severe-injury report for Improved Piping Products INC. is published. One employer, no account, unsubscribe in one click.
Site address
4311 DIRECTOR DR
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
4311 DIRECTOR DR., SAN ANTONIO, TX 78219
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
80
Ownership type
A

4 citations on file for this inspection.

1910.184 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 19, 2015
Abate by
Jul 9, 2015
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.184(c)(1): Slings that were damaged or defective were used:  Production Area, 4311 Director Drive:  On or about February 11, 2015, and at times prior thereto, employees were exposed to a struck-by hazard while using a damaged synthetic sling connected to Crane 1 to lift a part onto the 36 inch Bullard Vertical Turret Lathe.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.212 A01

Other-than-serious 1 instance 2 exposed
Issued
Jun 19, 2015
Abate by
Jul 9, 2015
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc:       Compression # 2 Area, 5040 Space Center:  On or about February 11, 2015, and at times prior thereto, employees were exposed to a caught in hazard, while using an Optimus Lift2k Lift Table to lift compression tools that did not have a guard to protect the employees from getting their foot caught between the table and the floor.
Recent events (2)
  • — I (O) $1260
  • — Z (S) $2100

1910.243 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 19, 2015
Abate by
Jul 9, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.243(c)(1): General requirements. Abrasive wheels were not used only on machine provided with safety guards as defined in paragraph (c)(1) through (4) of this section:     a)  Production Area, 4311 Director Drive:  On or about February 11, 2015, and at times prior thereto, employees were exposed to the hazard of being struck by flying projectiles, while using a Makita Angle Grinder without a guard to grind out defects on the pipes.    b)  Compression #2 Area, 5040 Space Center:  On or about February 11, 2015, and at times prior thereto, employees were exposed to the hazard of being struck by flying projectiles, while using a DeWalt Angle Grinder without a guard to grind off bolts on pieces of equipment.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.242 B

Repeat Gravity 5 1 instance 2 exposed
Issued
Jun 19, 2015
Abate by
Jul 9, 2015
Penalty
Initial $5,600 · Current $3,360 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  Maintenance Area, 5040 Space Center:  On or about February 11, 2015, and at times prior thereto, employees were exposed to the hazard of being struck by flying projectiles, while using compressed air at pressures greater than 30 p.s.i. to remove debris and metal shavings from a metal work table.  Improved Piping Products Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.242(b), which was contained in OSHA inspection number 977722, citation number 1, item number 3 and was affirmed as a final order on 9/4/14, with respect to a workplace located at 4311 Director Drive, San Antonio, TX 78219.
Recent events (2)
  • — I (R) $3360
  • — Z (R) $5600