Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLAGLER COOPERATIVE ASSOCIATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FLAGLER COOPERATIVE ASSOCIATION in 420 NOLAN, GENOA, CO 80818 (NAICS 493130). OSHA activity number 339795072.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flagler Cooperative Association — free Get an email when a new federal OSHA severe-injury report for Flagler Cooperative Association is published. One employer, no account, unsubscribe in one click.
Site address
420 NOLAN
City
GENOA
State
CO
ZIP
80818
Mailing
BOX 398, FLAGLER, CO 80815
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493130
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.23 A08

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2014
Abate by
Oct 8, 2014
Penalty
Initial $2,975 · Current $1,487 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk was not guarded:    (a)  On or about June 4, 2014, and at times prior, employees were exposed to falls into grain silos in the distributor room where the 22 elevator chute openings on the floor were not guarded.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1487
  • — Z (S) $2975

1910.23 E03 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 12, 2014
Abate by
Oct 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types were not of such construction that the completed structure was capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail:  (a)  On or about June 4, 2014, and at times prior, employees were exposed to falls of greater than four feet from the platform around the head of the distributor where the guard rail on the northeast side was not adequately anchored such that it wobbled loosely.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.27 D01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 12, 2014
Abate by
Oct 8, 2014
Penalty
Initial $2,975 · Current $1,487 Reduced
29 CFR 1910.27(d)(1)(ii): Cages or wells shall be provided for fixed ladders of more than 20 feet (except as provided in subparagraph 5 of this paragraph) to a maximum unbroken length of 30 feet:    (a)  On or about June 4, 2014, and at times prior, employees were exposed to fall hazards from a fixed ladder on the south side of the grain elevator that was approximately 35 feet high that did not have a cage or a ladder safety device.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1487
  • — Z (S) $2975

1910.134 C02 II

Other-than-serious 1 instance 1 exposed
Issued
Sep 12, 2014
Abate by
Oct 30, 2014
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    (a) On or about June 4, 2014, and at times prior, an employee voluntarily used a tight-fitting half-face respirator while cleaning the flat storage areas and working in other dusty areas without having had a medical evaluation.      Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $1190
  • — Z (S) $2380

1910.305 B01 II

Other-than-serious 1 instance 6 exposed
Issued
Sep 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a)  On or about June 4, 2014, and at times prior, a hole in the bottom of the "Electrical Controls" box on the outside of the elevator building on the west side south of the garage bay, was open.   (b)  On or about June 4, 2014, and at times prior, the cover for an electrical box in the elevator motor control room adjacent to the dump pit, was not fully closed exposing a gap in which dust could accumulate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Flagler Cooperative Association's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339795072.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.