GENOA, CO —
OSHA Inspection: FLAGLER COOPERATIVE ASSOCIATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FLAGLER COOPERATIVE ASSOCIATION in 420 NOLAN, GENOA, CO 80818 (NAICS 493130). OSHA activity number 339795072.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLAGLER COOPERATIVE ASSOCIATION
- Site address
- 420 NOLAN
- City
- GENOA
- State
- CO
- ZIP
- 80818
- Mailing
- BOX 398, FLAGLER, CO 80815
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493130
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 A08
- Issued
- Sep 12, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $2,975 · Current $1,487 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk was not guarded: (a) On or about June 4, 2014, and at times prior, employees were exposed to falls into grain silos in the distributor room where the 22 elevator chute openings on the floor were not guarded. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1487
- — Z (S) $2975
1910.23 E03 IV
- Issued
- Sep 12, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types were not of such construction that the completed structure was capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail: (a) On or about June 4, 2014, and at times prior, employees were exposed to falls of greater than four feet from the platform around the head of the distributor where the guard rail on the northeast side was not adequately anchored such that it wobbled loosely. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.27 D01 II
- Issued
- Sep 12, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $2,975 · Current $1,487 Reduced
General-duty citation text
29 CFR 1910.27(d)(1)(ii): Cages or wells shall be provided for fixed ladders of more than 20 feet (except as provided in subparagraph 5 of this paragraph) to a maximum unbroken length of 30 feet: (a) On or about June 4, 2014, and at times prior, employees were exposed to fall hazards from a fixed ladder on the south side of the grain elevator that was approximately 35 feet high that did not have a cage or a ladder safety device. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1487
- — Z (S) $2975
1910.134 C02 II
- Issued
- Sep 12, 2014
- Abate by
- Oct 30, 2014
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (a) On or about June 4, 2014, and at times prior, an employee voluntarily used a tight-fitting half-face respirator while cleaning the flat storage areas and working in other dusty areas without having had a medical evaluation. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $1190
- — Z (S) $2380
1910.305 B01 II
- Issued
- Sep 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about June 4, 2014, and at times prior, a hole in the bottom of the "Electrical Controls" box on the outside of the elevator building on the west side south of the garage bay, was open. (b) On or about June 4, 2014, and at times prior, the cover for an electrical box in the elevator motor control room adjacent to the dump pit, was not fully closed exposing a gap in which dust could accumulate.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Flagler Cooperative Association
View Flagler Cooperative Association's full OSHA safety record →
More inspections in this industry (NAICS 493130)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339795072.