Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLAGLER COOPERATIVE ASSOCIATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FLAGLER COOPERATIVE ASSOCIATION in 221 E 2ND ST, FLAGLER, CO 80815 (NAICS 424510). OSHA activity number 341183861.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flagler Cooperative Association — free Get an email when a new federal OSHA severe-injury report for Flagler Cooperative Association is published. One employer, no account, unsubscribe in one click.
Site address
221 E 2ND ST
City
FLAGLER
State
CO
ZIP
80815
Mailing
PO BOX 398, FLAGLER, CO 80815
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
10
Ownership type
A

9 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 2 instances 6 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    (a)  On or about January 15, 2016, and at times prior, the employer did not ensure that employees had free and clear access to the exit from the north side of the conveyor belt in the tunnel under the west grain storage bins, where the doors were locked and sealed requiring workers to climb under the conveyor belt to exit.    (b)  On or about January 15, 2016, and at times prior the employer did not ensure that employees had free and clear access to the emergency exits from the east metal grain bins in that the exits from the emergency evacuation ladders were locked during operations when employees were on top of the bins.     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a)  On or about January 15, 2016, and at times prior, employees were exposed to caught-in hazards from the unguarded pulleys of the personnel lift at the motor pulley on the distributor head level in the west bins.      Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 B07 IV

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:    (a)  On or about January 15, 2016, and at times prior, the control box to reset the fan for the York conveyor on top of the west concrete bins on the north side, was broken and no longer weather proof exposing employees to shock and fire hazards.      Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.303 G01 II

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   (a) On or about January 15, 2016, and at times prior, the employer did not ensure that employees were protected from electrical and fire hazards in that the electrical panels in the following locations were blocked from access:  1)  In the electrical room in the feed mill, panels were blocked by seats, trash cans and tools. 2)  On the west wall next to the north facing bay door in the tug room, the electrical boxes were blocked by brooms, buckets, and other material. 3)  In the electrical room from where the augers for the west grain storage are controlled, had cardboard storedin front of the electrical panels.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners (Note: Temporary electrical power and lighting installation(s) may only be used as specified by 1910.305(a)(2)(i)(A) through 1910.305(a)(2)(i)(C)):  (a) On or about January 15, 2016, and at times prior, employees were exposed to shock and fire hazards from the extension cord that powered the exhaust fan in the boot pit at the east elevator, which had been installed in the previous year.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards (Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard):    (a)  On or about January 15, 2016, and at times prior, employees were exposed to fall of about 100 feet on the east metal grain bins where employees perform maintenance on the distributor.      Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").    Flagler Cooperative Association was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.23(c)(1), which was contained in OSHA inspection number 429771, citation number 1, item number 1, and was affirmed as a final order on May 31, 2012, with respect to a workplace located at 221 E. 3nd St., Flagler, CO 80815.
Recent events (2)
  • — I (S) $3500
  • — Z (R) $7000

1910.305 B01 II

Serious 1 instance 4 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $200 · Current $100 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) On or about January 15, 2016, and at times prior, a hole in the side of the electrical junction box on the north west side of bin number 105 connecting the Balldor Industrial Motor fan motor to the bin, was not effectively closed to prevent dust or moisture from entering the box.  It was covered with tape.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").    Flagler Cooperative Association was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(1)(ii), which was contained in OSHA inspection number 979507, citation number 2, item number 1, and was affirmed as a final order on September 30, 2014, with respect to a workplace located at 240 Nolan in Genoa, Colorado.
Recent events (2)
  • — I (S) $100
  • — Z (R) $200

1910.23 A08

Other-than-serious 1 instance 3 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:  (a)  On or about January 15, 2016, and at times prior, employees were not protected from trip and fall hazards in two locations:  1)  In the floor at the distributor head of the west grain elevator, a hatch next the distributor leg cover was not fully covered by expanded metal.    2)  The catwalk above the ground storage had a hole around the conveyor motor.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.242 B

Other-than-serious 1 instance 4 exposed
Issued
Apr 6, 2016
Abate by
Apr 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a) On or about January 15, 2016, and at times prior, the employees were exposed to flying chips and other forced-air hazards from the compressed air that had a pressure of 45 p.s.i. which was used for blowing down machinery in the feed mill.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Flagler Cooperative Association's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341183861.