FLAGLER, CO —
OSHA Inspection: FLAGLER COOPERATIVE ASSOCIATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FLAGLER COOPERATIVE ASSOCIATION in 221 E 2ND ST, FLAGLER, CO 80815 (NAICS 424510). OSHA activity number 341183861.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLAGLER COOPERATIVE ASSOCIATION
- Site address
- 221 E 2ND ST
- City
- FLAGLER
- State
- CO
- ZIP
- 80815
- Mailing
- PO BOX 398, FLAGLER, CO 80815
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 10
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.37 A03
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) On or about January 15, 2016, and at times prior, the employer did not ensure that employees had free and clear access to the exit from the north side of the conveyor belt in the tunnel under the west grain storage bins, where the doors were locked and sealed requiring workers to climb under the conveyor belt to exit. (b) On or about January 15, 2016, and at times prior the employer did not ensure that employees had free and clear access to the emergency exits from the east metal grain bins in that the exits from the emergency evacuation ladders were locked during operations when employees were on top of the bins. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.219 D01
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about January 15, 2016, and at times prior, employees were exposed to caught-in hazards from the unguarded pulleys of the personnel lift at the motor pulley on the distributor head level in the west bins. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.303 B07 IV
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: (a) On or about January 15, 2016, and at times prior, the control box to reset the fan for the York conveyor on top of the west concrete bins on the north side, was broken and no longer weather proof exposing employees to shock and fire hazards. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.303 G01 II
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) On or about January 15, 2016, and at times prior, the employer did not ensure that employees were protected from electrical and fire hazards in that the electrical panels in the following locations were blocked from access: 1) In the electrical room in the feed mill, panels were blocked by seats, trash cans and tools. 2) On the west wall next to the north facing bay door in the tug room, the electrical boxes were blocked by brooms, buckets, and other material. 3) In the electrical room from where the augers for the west grain storage are controlled, had cardboard storedin front of the electrical panels. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 I
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners (Note: Temporary electrical power and lighting installation(s) may only be used as specified by 1910.305(a)(2)(i)(A) through 1910.305(a)(2)(i)(C)): (a) On or about January 15, 2016, and at times prior, employees were exposed to shock and fire hazards from the extension cord that powered the exhaust fan in the boot pit at the east elevator, which had been installed in the previous year. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.23 C01
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards (Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard): (a) On or about January 15, 2016, and at times prior, employees were exposed to fall of about 100 feet on the east metal grain bins where employees perform maintenance on the distributor. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet"). Flagler Cooperative Association was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.23(c)(1), which was contained in OSHA inspection number 429771, citation number 1, item number 1, and was affirmed as a final order on May 31, 2012, with respect to a workplace located at 221 E. 3nd St., Flagler, CO 80815.
Recent events (2)
- — I (S) $3500
- — Z (R) $7000
1910.305 B01 II
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $200 · Current $100 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about January 15, 2016, and at times prior, a hole in the side of the electrical junction box on the north west side of bin number 105 connecting the Balldor Industrial Motor fan motor to the bin, was not effectively closed to prevent dust or moisture from entering the box. It was covered with tape. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet"). Flagler Cooperative Association was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(1)(ii), which was contained in OSHA inspection number 979507, citation number 2, item number 1, and was affirmed as a final order on September 30, 2014, with respect to a workplace located at 240 Nolan in Genoa, Colorado.
Recent events (2)
- — I (S) $100
- — Z (R) $200
1910.23 A08
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: (a) On or about January 15, 2016, and at times prior, employees were not protected from trip and fall hazards in two locations: 1) In the floor at the distributor head of the west grain elevator, a hatch next the distributor leg cover was not fully covered by expanded metal. 2) The catwalk above the ground storage had a hole around the conveyor motor. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.242 B
- Issued
- Apr 6, 2016
- Abate by
- Apr 20, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) On or about January 15, 2016, and at times prior, the employees were exposed to flying chips and other forced-air hazards from the compressed air that had a pressure of 45 p.s.i. which was used for blowing down machinery in the feed mill. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Flagler Cooperative Association
View Flagler Cooperative Association's full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341183861.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.