WEST BEND, WI —
OSHA Inspection: ADVANCED COATINGS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ADVANCED COATINGS, INC. in 304 PROGRESS DRIVE, WEST BEND, WI 53095 (NAICS 332812). OSHA activity number 339810723.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED COATINGS, INC.
- Site address
- 304 PROGRESS DRIVE
- City
- WEST BEND
- State
- WI
- ZIP
- 53095
- Mailing
- 304 PROGRESS DRIVE, WEST BEND, WI 53095
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 31
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.107 B05 I
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $5,400 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): The spraying operations, except electrostatic spraying operations, were not designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute: (a) Paint booth 1 had an average air velocity of 84 linear feet per minute at the open face. (b) Paint booth 3 had an average air velocity of 44 linear feet per minute at the open face. (c) Paint booth 4 had an average air velocity of 88 linear feet per minute at the open face.
Recent events (2)
- — I (S) $2100
- — Z (S) $5400
1910.107 B05 IV
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: (a) Paint booth 1 had no sprinklers in the booth nor behind the filters. (b) Paint booth 2 had no sprinklers in the booth nor behind the filters. (c) Paint booth 3 had no sprinklers in the booth nor behind the filters. (d) Paint booth 4 had no sprinklers in the booth nor behind the filters.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B06
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(6): Each spray booth having a frontal area larger than 9 square feet did not have a metal deflector or curtain not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening: (a) There was no metal deflector installed at paint booth 1 with a frontal area of 100 square feet. (b) There was no metal deflector installed at paint booth 2 with a frontal area of 110 square feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G02
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: (a) Paint booth 1 had an accumulation of paint overspray on the front edges of the paint booth. (b) Paint booth 2 had an accumulation of paint overspray on the front edges of the paint booth. (c) Paint booth 3 had an accumulation of paint overspray on the front edges of the paint booth. (d) Paint booth 4 had an accumulation of paint overspray on the front edges of the paint booth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G07
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color background were not conspicuously posted at all spraying areas and paint storage rooms: (a) A "No Smoking" sign was not posted at paint booth number 1.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 M01
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(m)(1): Spraying operations involving the use of organic peroxides and other dual component coatings were not conducted in approved sprinklered spray booths meeting the requirements of this section: (a) At paint booth number 1 the painting was being done outside of and in front of the booth while using the dual component, epoxy primer and epoxy hardener, paint.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Oct 15, 2014
- Abate by
- Nov 17, 2014
- Penalty
- Initial $3,600 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Employees entered the parts drying ovens without utilizing the lockout standard operating procedure.
Recent events (2)
- — I (S) $2100
- — Z (S) $3600
1910.147 D04 I
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Employees entered the parts drying ovens without applying a lockout or tagout device.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E02 IV D
- Issued
- Oct 15, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: (a) Employees in the paint mixing room were allowed to draw Hentzen paint from the two 55-gallon drums that lacked self-closing valves.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 D03 III B 2
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life: (a) The employer did not implement a respirator cartridge change schedule for the painters and paint mixers who were required to wear negative pressure half-face piece respirators.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06
- Issued
- Oct 15, 2014
- Abate by
- Oct 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: (a) The employer did not ensure that the two sprayers that contained rust preventative were labeled with the identity and hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Advanced Coatings, INC.
View Advanced Coatings, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339810723.