Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEHIGH TECHNOLOGIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LEHIGH TECHNOLOGIES, INC. in 120 ROYAL WOODS COURT SW, TUCKER, GA 30084 (NAICS 326299). OSHA activity number 339895898.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lehigh Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Lehigh Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
120 ROYAL WOODS COURT SW
City
TUCKER
State
GA
ZIP
30084
Mailing
120 ROYAL WOODS COURT S.W. STE F, TUCKER, GA 30084
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326299
Employees
92
Ownership type
A

2 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 27, 2014
Abate by
Sep 23, 2014
Penalty
Initial $1,890 · Current $945 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.  On or about 8/11/2014, at the Tucker facility, employees cleaning the shaker machines and surrounding areas were not applying locks to the equipment in which they were cleaning.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $945
  • — Z (S) $1890

1910.147 C07 I A

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 27, 2014
Abate by
Sep 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  On or about 8/11/14, at the Tucker facility, employees trained as "Affected" employees were performing "Authorized" activities of cleaning equipment in the production area but were not trained to lockout the equipment they were cleaning themselves.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Lehigh Technologies, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339895898.