Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SPECTRUM MACHINE INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of SPECTRUM MACHINE INC. in 7071 PECK RD, RAVENNA, OH 44266 (NAICS 331522). OSHA activity number 339923880.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spectrum Machine INC. — free Get an email when a new federal OSHA severe-injury report for Spectrum Machine INC. is published. One employer, no account, unsubscribe in one click.
Site address
7071 PECK RD
City
RAVENNA
State
OH
ZIP
44266
Mailing
1668 FROST ROAD, STREETSBORO, OH 44241
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331522
Employees
22
Ownership type
A

4 citations on file for this inspection.

1910.133 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 17, 2014
Abate by
Dec 27, 2014
Penalty
Initial $2,310 · Current $2,300 Reduced
29 CFR  1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:     On the day of the inspection an employee working at the Hem-saw, who used an air hose to clean the metal chips from the saw, did not wear safety glasses with side-shields.
Recent events (2)
  • — I (S) $2300
  • — Z (S) $2310

1910.134 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 17, 2014
Abate by
Dec 27, 2014
Penalty
Initial $5,390 · Current $0 Reduced
29 CFR 1910.134(a)(1):   When effective engineering controls were not feasible or while they were being instituted, appropriate respirators were not used pursuant to the requirements of this section:    On 10/29/14, a Furnace operator working in the casting department was exposed to copper at an 8 hour time weighted average level of 0.11 mg/m3, this exposure was approximately 1.1 times the permissible exposure limit (PEL) of 0.1 mg/m3.  This employee did not wear the respirator consistently, only when working under the pouring deck.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5390

1910.1000 A02

Repeat Gravity 5 1 instance 2 exposed
Issued
Dec 17, 2014
Abate by
Oct 5, 2015
Penalty
Initial $7,700 · Current $5,400 Reduced

Hazardous substances 0731

29 CFR 1910.1000(a)(2):  Employees were exposed to an airborne concentration of Copper, listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 0.1 milligrams per cubic meter of air (mg/m3):      a)  On 10/29/14, a Casting hand working in the casting department was exposed to copper at an 8 hour time weighted average level of 0.11 mg/m3, this exposure was approximately 1.1 times the permissible exposure limit (PEL) of 0.1 mg/m3.  This exposure was calculated from a sample collected over a 471 minute period; a zero increment was included for the 9 minutes not sampled.      b)  On 10/29/14, a Furnace operator working in the casting department was exposed to copper at an 8 hour time weighted average level of 0.11 mg/m3, this exposure was approximately 1.1 times the permissible exposure limit (PEL) of 0.1 mg/m3.  This exposure was calculated from a sample collected over a 480 minute period.    Spectrum Machine was previously cited for a violation of this occupational safety and health standard , which was contained in OSHA inspection number 858103, citation number 1, item number 8a and was affirmed as a final order on 8/15/2013, with respect to the workplace at this location.
Recent events (2)
  • — I (R) $5400
  • — Z (R) $7700

1910.1000 E

Repeat Gravity 5 1 instance 2 exposed
Issued
Dec 17, 2014
Abate by
Oct 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e):  Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):      Engineering controls were not implemented to reduce the exposure to employees overexposed to Copper.      Engineering controls usually effective in these circumstances include, but are not limited to, the following:      1.   Modification of the existing ventilation system to improve capture of air contaminants at the ventilation hoods.      2.   Modification of ventilation hoods to better collect metal fumes.      3.  Installation of exhaust hoods over the buckets used to collect slag.      Abatement Steps      STEP 1:  Submit to the Area Director a written detailed plan of abatement outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposures as referenced in this citation.  This plan shall include, at a minimum, target dates for the following actions which must be consistent with the dates required by this citation.      a)  Evaluation of the extent and location of the hazard source.      b)  Evaluation of control measure options.      c)  Selection of optimum control method(s).      d)  Determination of control measure design.      e)  Ordering and delivery of equipment and material(s).      f)  Installation of control measures.      g)  Training of employees in proper operation and maintenance of newly-implemented control measures.      h)  Assurance of effective performance of control measures.      All proposed control measures shall be evaluated for each particular use by a technically qualified person.  Abatement must be completed by ***30 days***.      STEP 2:  Correction should have been completed by the implementation of feasible engineering and/or administrative controls and air sampling results to verify the effectiveness in achieving compliance.  Abatement must be completed by ***60 days***.    Spectrum Machine was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 858103, citation number 1, item number 8b and was affirmed as a final order on 8/15/2013, with respect to the workplace at this location.
Recent events (2)
  • — I (R) $0
  • — Z (R) $0

View Spectrum Machine INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339923880.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.