RAVENNA, OH —
OSHA Inspection: SPECTRUM MACHINE INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of SPECTRUM MACHINE INC. in 7071 PECK RD, RAVENNA, OH 44266 (NAICS 331522). OSHA activity number 341853851.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPECTRUM MACHINE INC.
- Site address
- 7071 PECK RD
- City
- RAVENNA
- State
- OH
- ZIP
- 44266
- Mailing
- 1668 FROST ROAD, STREETSBORO, OH 44241
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331522
- Employees
- 24
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1000 A02
- Issued
- Jan 26, 2017
- Abate by
- Mar 15, 2017
- Penalty
- Initial $31,689 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Copper Fume, listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 0.1 milligrams per cubic meter of air (mg/m3): a). On or about November 10, 2016, a vertical casting operator working on the vertical caster was exposed to copper fume at an 8 hour time weighted average level of 0.118 mg/m3, this exposure was approximately 1.18 times the permissible exposure limit (PEL) of 0.1mg/m3. This exposure was calculated from a sample collected over a 388 minute period; a zero increment was included for the 92 minutes not sampled. b). On or about November 10, 2016, a vertical casting operator working on the vertical caster was exposed to copper fume at an 8 hour time weighted average level of 0.188 mg/m3, this exposure was approximately 1.88 times the permissible exposure limit (PEL) of 0.1mg/m3. This exposure was calculated from a sample collected over a 396 minute period; a zero increment was included for the 84 minutes not sampled. Spectrum Machine, Inc., was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 992388, citation number 2, item number 1a and was affirmed as a final order on 1/12/2015, with respect to the workplace at this location.
Recent events (2)
- — I (R) $0
- — Z (R) $31689
1910.1000 E
- Issued
- Jan 26, 2017
- Abate by
- Mar 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): Engineering controls were not implemented to reduce the exposure to employees overexposed to Copper Fume. Engineering controls usually effective in these circumstances include, but are not limited to, the following: 1. Modification of the existing ventilation system to improve capture of air contaminants at the ventilation hoods. 2. Modification of ventilation hoods to better collect metal fumes. 3. Installation of exhaust hoods over the buckets used to collect slag. a). On or about November 10, 2016, a vertical casting operator working on the vertical caster was exposed to copper fume at an 8 hour time weighted average level of 0.118 mg/m3, this exposure was approximately 1.18 times the permissible exposure limit (PEL) of 0.1mg/m3. This exposure was calculated from a sample collected over a 388 minute period; a zero increment was included for the 92 minutes not sampled. b). On or about November 10, 2016, a vertical casting operator working on the vertical caster was exposed to copper fume at an 8 hour time weighted average level of 0.188 mg/m3, this exposure was approximately 1.88 times the permissible exposure limit (PEL) of 0.1mg/m3. This exposure was calculated from a sample collected over a 396 minute period; a zero increment was included for the 84 minutes not sampled. Spectrum Machine, Inc., was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 992388, citation number 2, item number 1b and was affirmed as a final order on 1/12/2015, with respect to the workplace at this location.
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at Spectrum Machine INC.
View Spectrum Machine INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331522)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341853851.