Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D-7 CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of D-7 CONSTRUCTION in LOT 164, WELSH DR., LAKE SAINT LOUIS, MO 63367 (NAICS 238160). OSHA activity number 339933335.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D-7 Construction — free Get an email when a new federal OSHA severe-injury report for D-7 Construction is published. One employer, no account, unsubscribe in one click.
Establishment
D-7 CONSTRUCTION
Site address
LOT 164, WELSH DR.
City
LAKE SAINT LOUIS
State
MO
ZIP
63367
Mailing
P.O. BOX 191, WENTZVILLE, MO 63385
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Sep 16, 2014
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.102(a)(1): Employees were not provided or wore eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:   At the job site, the employer failed to ensure that employee(s) wore safety glasses while operating a Masterforce nail gun on a residential roof.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.1053 B01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 16, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  At the job site, for employee(s) performing roofing activities upon a residential roof, the ladder used for access/egress extended approximately 24 inches above the landing surface.  The fall distance was approximately 8 feet to the lower porch landing and approximately 20 feet ground to eave height.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.1053 B06

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level:  At the job site, for employee(s) performing roofing activities upon a residential roof, the unsecured ladder used for access/egress was located on the 3:12 porch roof. The fall distance was approximately 8 feet to the lower porch landing and approximately 20 feet ground to eave height.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View D-7 Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339933335.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.