Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TROY CHEMICAL CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TROY CHEMICAL CORPORATION in 1 AVENUE L, NEWARK, NJ 07105 (NAICS 325510). OSHA activity number 340034594.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Troy Chemical Corporation — free Get an email when a new federal OSHA severe-injury report for Troy Chemical Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1 AVENUE L
City
NEWARK
State
NJ
ZIP
07105
Mailing
1 AVENUE L, NEWARK, NJ 07105
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
77
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Apr 2, 2015
Abate by
Apr 14, 2015
Penalty
Initial $4,900 · Current $0 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration or other fire hazards from ignition of combustible dust in ungrounded dust conveyors.  a) Building 71, dryer D-7108 conveyor   Two grounding wires for the conveyor from dryer D-7108 to packaging were not connected.  The conveyor carried Polyphase P-100 powder, a Class II explosive dust.  Violation occurred on or about 10/24/14.
Recent events (3)
  • — F (S) $0
  • — C (S) $4900
  • — Z (S) $4900

1910.178 C02 IV

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Apr 2, 2015
Abate by
Apr 28, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.178(c)(2)(iv): Power-operated industrial trucks designated as DY, EE, or EX were not used in locations where volatile flammable liquids or flammable gases were  handled, processed or used, but in which the hazardous liquids, vapors or gases were normally confined within closed containers or closed systems from which they could escape only in case of accidental rupture or breakdown of such containers or systems, or in the case of abnormal operation of equipment:  a)  Building 71, bagging area nearest Part I reactor.  A Crown LPS propane forklift was used to remove product from the bagging area which has an electrical classification of Class 1 Division 1.  Violation occurred on or about 10/24/14.
Recent events (3)
  • — F (S) $0
  • — C (S) $4900
  • — Z (S) $4900

View Troy Chemical Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340034594.