NEWARK, NJ —
OSHA Inspection: TROY CHEMICAL CORPORATION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of TROY CHEMICAL CORPORATION in ONE AVENUE L, NEWARK, NJ 07105 (NAICS 325510). OSHA activity number 346780935.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TROY CHEMICAL CORPORATION
- Site address
- ONE AVENUE L
- City
- NEWARK
- State
- NJ
- ZIP
- 07105
- Mailing
- ONE AVENUE L, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 85
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II C
- Issued
- Dec 7, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $10,938 · Current $15,625
A615
General-duty citation text
1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance, including, but not limited to the specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: On June 13,2023, the employer did not ensure that its written LOTO procedures included the specific steps for the placement, removal and transfer of lockout devices for Tank Farm 300 Storage P-321 AMP 95 Pump.
Recent events (2)
- — I (O) $15625
- — Z (S) $10938
1910.147 C07 III A
- Issued
- Dec 7, 2023
- Abate by
- Jan 2, 2024
- Penalty
- Initial $0 · Current $0
A615
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures: On June 13, 2023, the employer had not provided retraining to authorized employees on the LOTO procedures for the Tank Farm 300 Storage P-321 AMP 95 Pump when employees deviated from the procedures.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Troy Chemical Corporation
View Troy Chemical Corporation's full OSHA safety record →
More inspections in this industry (NAICS 325510)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346780935.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.