OSHA Inspection: IVEX PROTECTIVE PACKAGING INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of IVEX PROTECTIVE PACKAGING INC. in 2560 CAMPBELL RD., SIDNEY, OH 45365 (NAICS 326150). OSHA activity number 340168772.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ivex Protective Packaging INC. — free Get an email when a new federal OSHA severe-injury report for Ivex Protective Packaging INC. is published. One employer, no account, unsubscribe in one click.
Site address
2560 CAMPBELL RD.
City
SIDNEY
State
OH
ZIP
45365
Mailing
456 S. STOLLE DRIVE, SIDNEY, OH 45365
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326150
Employees
20
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
May 27, 2015
Abate by
Sep 28, 2015
Penalty
Initial $6,930 · Current $3,465 Reduced

Hazardous substances K105

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards while operating the polyethylene foam densifier.    a. IVEX Protective Packaging Inc. located in Sidney, Ohio:  On or about January 8, 2015, employees operating the polyethylene foam densifier located in the production area of the facility, were exposed to fire and explosion hazards from the accumulation and ignition of isobutane gases inside of the equipment.    Among other methods, one feasible and acceptable method to correct this hazard includes, but is not limited to: 1. Ensure raw material is sufficiently pre-processed to remove all isobutane or other flammable gases prior to placement in the densifier; 2. Provide sufficient ventilation to the densifier to ensure flammable gas concentrations do not exceed the lower flammable limit; 3. Eliminate all possible sources of ignition in the densifier, including static electricity.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6930

1910.23 C01

Serious Gravity 5 1 instance 3 exposed
Issued
May 27, 2015
Abate by
Jun 5, 2015
Penalty
Initial $3,960 · Current $1,980 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there was entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toe board wherever, beneath the open sides.    a. IVEX Protective Packaging Inc. located in Sidney, Ohio:  On or about January 8, 2015, the employer did not ensure the work platform surrounding the densifier was equipped with a mid-rail, exposing employees to a fall hazard of 55 inches.
Recent events (2)
  • — I (S) $1980
  • — Z (S) $3960

1910.132 A

Repeat Gravity 10 1 instance 3 exposed
Issued
May 27, 2015
Abate by
Jun 5, 2015
Penalty
Initial $13,860 · Current $6,930 Reduced

Hazardous substances K105

29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.    a. IVEX Protective Packaging Inc. located in Sidney, Ohio:  On or about January 8, 2015, the employer did not ensure employees operating the densifier were wearing flame retardant clothing to protect the torso and arms.    IVEX Protective Packaging Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.132(a), which was contained in OSHA inspection number 850603, citation number 1, item number 18 and was affirmed as a final order on August 12, 2013, with respect to a workplace located at 456 S. Stolle Drive, Sidney, Ohio.