OSHA Inspection: CUSTOM PLASTIC SPECIALTIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CUSTOM PLASTIC SPECIALTIES, INC. in 5678 WEST RIDGE ROAD, ERIE, PA 16506 (NAICS 323111). OSHA activity number 340215474.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custom Plastic Specialties, INC. — free Get an email when a new federal OSHA severe-injury report for Custom Plastic Specialties, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5678 WEST RIDGE ROAD
City
ERIE
State
PA
ZIP
16506
Mailing
5678 WEST RIDGE ROAD, ERIE, PA 16506
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
123
Ownership type
A

7 citations on file for this inspection.

1910.24 H

Serious Gravity 1 2 instances 10 exposed
Issued
May 4, 2015
Abate by
Jun 29, 2015
Penalty
Initial $2,700 · Current $1,200 Reduced
29 CFR 1910.24(h): Stair railings and handrails were not installed in accordance with the provisions of 1910.23:     a) Custom Plastic Specialties, stairways to the loft/ upper mezzanine areas and offices.  On or about January 29, 2015, the guardrail system on the stairways were not equipped with a mid-rail.  The stairways were utilized to access and egress the upper levels.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2700

1910.145 C03

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
May 4, 2015
Abate by
May 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(3): Safety instruction signs were not used where there is a need for general instructions and suggestions relative to safety measures:  a) Custom Plastic Specialties, loading area from loft.  On or about January 29, 2015, a safety instruction sign was not posted at and/or near the loading area to warn and instruct employees of the potential fall hazards that could be encountered if they proceeded past the chain that was strung across the loading area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B04

Serious Gravity 1 1 instance 2 exposed
Issued
May 4, 2015
Abate by
Jun 29, 2015
Penalty
Initial $2,700 · Current $1,500 Reduced
29 CFR 1910.37(b)(4): When the direction of travel to the exit or exit discharge is not immediately apparent, signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge:     a) Custom Plastic Specialties, mezzanine/loft.  On or about January 29, 2015, signs indicating the direction of exits were not installed in the loft area.  The exit route and to the nearest exit door was not readily apparent.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2700

1910.37 A04

Serious Gravity 1 1 instance 85 exposed
Issued
May 4, 2015
Abate by
Jun 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) were not maintained in proper working order at all times:     a) Custom Plastic Specialties, 5678 West Ridge Road Erie, PA.  On or about January 29, 2015, exit signs were not illuminated.  These exit signs were equipped with internal illumination sources were not functioning.  The exit signs were located in areas of the building that included, but were not limited to:       (1) Exit door - employee main side entrance   (2) Exit door - west side of building   (3) Exit door - northeast side by eyewash station/stairs
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II

Serious Gravity 5 1 instance 8 exposed
Issued
May 4, 2015
Abate by
Jun 29, 2015
Penalty
Initial $4,500 · Current $3,000 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, items A through D of this section:      a) Custom Plastic Specialties, 5678 West Ridge Road Erie, PA.  On or about January 29, 2015, and at times prior thereto, a specific energy control procedure (lockout tagout procedure) was not developed and documented for the HuiLong Blow Molding Press.  The only procedure for the machine was a generic procedure that did not contain the specific methods, techniques, and procedural elements outlined in 29 CFR 1910.147(c)(4)(ii)(A) through 29 CFR 1910.147(c)(4)(ii)(D)
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4500

1910.147 C06 I

Serious Gravity 5 1 instance 40 exposed
Issued
May 4, 2015
Abate by
Jun 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:    a) Custom Plastic Specialties, 5678 West Ridge Road Erie, PA.  On or about January 29, 2015, employees conducted servicing and maintenance work on machines/equipment that included but was not limited to laminators, plastic blow molding machines, and bagging machines.  Annual periodic inspections of the lockout/tagout procedures (energy control procedures) had not been conducted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 10 exposed
Issued
May 4, 2015
Abate by
Jun 29, 2015
Penalty
Initial $5,400 · Current $2,700 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, pinchpoints, and moving parts:     a) Custom Plastic Specialties, 5678 West Ridge Road Erie, PA, Blow Molding Department.  On or about January 29, 2015, employees were exposed to the hazards associated with unguarded moving parts of the HuiLong Blow Molding Press.  These moving parts included but were not limited to the moving arms and moving/indexing mold holder located inside the machine.  Employees were exposed to the moving parts when reaching inside the machine to place parts.     b) Custom Plastic Specialties, 5678 West Ridge Road Erie, PA, assembly area - bagger machine.  On or about January 29, 2015, employees were exposed to hand and finger injuries from the unguarded moving doors and sealing mechanisms on the bagger machine.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $5400

View Custom Plastic Specialties, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340215474.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.