ERIE, PA —
OSHA Inspection: CUSTOM PLASTIC SPECIALTIES, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of CUSTOM PLASTIC SPECIALTIES, INC. in 5678 WEST RIDGE ROAD, ERIE, PA 16506 (NAICS 323111). OSHA activity number 342403037.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM PLASTIC SPECIALTIES, INC.
- Site address
- 5678 WEST RIDGE ROAD
- City
- ERIE
- State
- PA
- ZIP
- 16506
- Mailing
- 5678 WEST RIDGE ROAD, ERIE, PA 16506
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 190
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.219 C04 I
- Issued
- Dec 7, 2017
- Abate by
- Jan 4, 2018
- Penalty
- Initial $6,519 · Current $3,900 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) projected more than one half the diameter of the shaft: A.) Custom Plastic Specialties, Inc., blow mold room, end of conveyer line for blow mold machine #3/#4, on or about June 15, 2017 and time prior thereto: The conveyer line was equipped with an unguarded end shaft. The end shaft on the conveyer was 1 inch in diameter and protruded 1-1/2 inches.
Recent events (2)
- — I (S) $3900
- — Z (S) $6519
1910.37 B02
- Issued
- Dec 7, 2017
- Abate by
- Jan 4, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": A.) Custom Plastic Specialties, Inc., northwest dock area exit door, on or about June 15, 2017 and time prior thereto: The exit door was not equipped with an exit sign.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- Dec 7, 2017
- Abate by
- Jan 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. A.) Custom Plastic Specialties, Inc., on or about June 15, 2017 and time prior thereto: Employees perform service and maintenance on equipment including, but not limited to, the HuiLong Blow Molding Press. Periodic inspections were not completed with all authorized employees performing service and maintenance.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Custom Plastic Specialties, INC.
View Custom Plastic Specialties, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342403037.