OSHA Inspection: W & L INSULATION & ROOFING INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of W & L INSULATION & ROOFING INC in 1200 MALONEY ROAD, KAUKAUNA, WI 54130 (NAICS 238160). OSHA activity number 340217660.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch W & L Insulation & Roofing INC — free Get an email when a new federal OSHA severe-injury report for W & L Insulation & Roofing INC is published. One employer, no account, unsubscribe in one click.
Site address
1200 MALONEY ROAD
City
KAUKAUNA
State
WI
ZIP
54130
Mailing
PO BOX 237, STOCKBRIDGE, WI 53088
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 13, 2015
Abate by
Apr 6, 2015
Penalty
Initial $2,640 · Current $1,452 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    a)  On or about 01-29-15, an employee was using an incorrectly installed personal fall arrest system which would have created a greater than six (6) ft. free fall.  The worker was using a 4 foot lanyard and a Type II retractable (SRL) between his body harness and anchor while working on the edge of a roof approximately 36 ft. above the lower level.
Recent events (2)
  • — I (S) $1452
  • — Z (S) $2640

1926.502 D17

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 13, 2015
Abate by
Apr 6, 2015
Penalty
Initial $2,640 · Current $1,452 Reduced
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:    a)  On or about 01-29-15, an employee was working on the edge of a roof approximately thirty-six (36) feet above the lower surface level using a personal fall arrest system with a body harness attachment point located below the center of the back.
Recent events (2)
  • — I (S) $1452
  • — Z (S) $2640

1926.503 A02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 13, 2015
Abate by
Apr 6, 2015
Penalty
Initial $1,760 · Current $968 Reduced
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the correct use and operation of personal fall arrest equipment.      a)  On or about 01-29-15, three employees were exposed to fall hazards without receiving adequate training on the use of personal fall arrest equipment.  One employee was not utilizing any fall protection equipment, one employee was wearing a body harness without attaching it to an anchored fall arrest system, and one employee had an incorrectly installed lifeline attached to an improperly donned body harness.
Recent events (2)
  • — I (S) $968
  • — Z (S) $1760

1926.503 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 13, 2015
Abate by
Apr 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a)  Employer did not provide written certification of required fall protection safety training for employees working at heights greater than six (6) feet.  Two employees had been working on a roof approximately thirty-six (36) ft. above surface level prior to company protocol of providing initial Maximum Fall Protection Program safety training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B10

Repeat Gravity 10 1 instance 2 exposed
Issued
Feb 13, 2015
Abate by
Apr 6, 2015
Penalty
Initial $15,400 · Current $8,470 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:    a)  On or about 01-29-15, two employees were working on the edge of a roof approximately thirty-six (36) feet above ground surface without utilizing fall protection equipment.    The W & L Insulation & Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(10), which was contained in OSHA inspection number 110201, citation number 01, item number 001 and was affirmed as a final order on 05-16-12, with respect to a workplace located at 635 Elmwood Avenue, Oshkosh, WI  54901.
Recent events (2)
  • — I (R) $8470
  • — Z (R) $15400

View W & L Insulation & Roofing INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340217660.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.