KAUKAUNA, WI —
OSHA Inspection: W & L INSULATION & ROOFING INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of W & L INSULATION & ROOFING INC in 1200 MALONEY ROAD, KAUKAUNA, WI 54130 (NAICS 238160). OSHA activity number 340217660.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- W & L INSULATION & ROOFING INC
- Site address
- 1200 MALONEY ROAD
- City
- KAUKAUNA
- State
- WI
- ZIP
- 54130
- Mailing
- PO BOX 237, STOCKBRIDGE, WI 53088
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.502 D16 III
- Issued
- Feb 13, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $2,640 · Current $1,452 Reduced
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) On or about 01-29-15, an employee was using an incorrectly installed personal fall arrest system which would have created a greater than six (6) ft. free fall. The worker was using a 4 foot lanyard and a Type II retractable (SRL) between his body harness and anchor while working on the edge of a roof approximately 36 ft. above the lower level.
Recent events (2)
- — I (S) $1452
- — Z (S) $2640
1926.502 D17
- Issued
- Feb 13, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $2,640 · Current $1,452 Reduced
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a) On or about 01-29-15, an employee was working on the edge of a roof approximately thirty-six (36) feet above the lower surface level using a personal fall arrest system with a body harness attachment point located below the center of the back.
Recent events (2)
- — I (S) $1452
- — Z (S) $2640
1926.503 A02 III
- Issued
- Feb 13, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $1,760 · Current $968 Reduced
General-duty citation text
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the correct use and operation of personal fall arrest equipment. a) On or about 01-29-15, three employees were exposed to fall hazards without receiving adequate training on the use of personal fall arrest equipment. One employee was not utilizing any fall protection equipment, one employee was wearing a body harness without attaching it to an anchored fall arrest system, and one employee had an incorrectly installed lifeline attached to an improperly donned body harness.
Recent events (2)
- — I (S) $968
- — Z (S) $1760
1926.503 B01
- Issued
- Feb 13, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) Employer did not provide written certification of required fall protection safety training for employees working at heights greater than six (6) feet. Two employees had been working on a roof approximately thirty-six (36) ft. above surface level prior to company protocol of providing initial Maximum Fall Protection Program safety training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B10
- Issued
- Feb 13, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $15,400 · Current $8,470 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) On or about 01-29-15, two employees were working on the edge of a roof approximately thirty-six (36) feet above ground surface without utilizing fall protection equipment. The W & L Insulation & Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(10), which was contained in OSHA inspection number 110201, citation number 01, item number 001 and was affirmed as a final order on 05-16-12, with respect to a workplace located at 635 Elmwood Avenue, Oshkosh, WI 54901.
Recent events (2)
- — I (R) $8470
- — Z (R) $15400
More inspections at W & L Insulation & Roofing INC
View W & L Insulation & Roofing INC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI