OSHA Inspection: DEVELOPING BUILDERS, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEVELOPING BUILDERS, LLC. in 351 RUCKER LANE, STATESBORO, GA 30458 (NAICS 238130). OSHA activity number 340299650.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Developing Builders, LLC. — free Get an email when a new federal OSHA severe-injury report for Developing Builders, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
351 RUCKER LANE
City
STATESBORO
State
GA
ZIP
30458
Mailing
2224 SUMMER CROSSING, MOBILE, AL 36695
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
14
Ownership type
A

5 citations on file for this inspection.

1926.501 B02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 24, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.501(b)(2)(ii): Each employee on a walking/working surface 6 feet (1.8 m) or more above a lower level where leading edges are under construction, but who was not engaged in the leading edge work, was not protected from falling by a guardrail system, safety net system, or personal fall arrest system:  a) At the site, on February 5, 2015, the employer did not ensure employees performing decking work at height of eleven feet above the ground level were protected from fall hazards through the use of a personal fall arrest system, guardrail system, or safety net systems, exposing the employees to the hazards associated with falling.
Recent events (1)
  • — Z (S) $1600

1926.405 G02 IV

Serious Gravity 1 1 instance 14 exposed
Issued
Feb 24, 2015
Abate by
Mar 6, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a) At the back of the house, on or about and at times prior to February 5, 2015, the employer did not ensure that the strain relief of a flexible cord of a "Bull" air compressor was intact and free of damage, exposing employees to the hazards associated with electrical shock and burns.
Recent events (1)
  • — Z (S) $1200

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 24, 2015
Abate by
Mar 6, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) At the job site, on February 5, 2015, the employer did not develop, implement, or maintain a written hazard communication program for employees who used "Titebond PROvantage Subfloor Adhesive" while installing the subflooring of the second floor of a two story residential home, exposing the employees to inhalation and absorption hazards.
Recent events (1)
  • — Z (S) $1200

1910.1200 G01

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 24, 2015
Abate by
Mar 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Chemical manufacturers and importers shall obtain or develop a material safety data sheet for each hazardous chemical they produce or import. Employers shall have a material safety data sheet in the workplace for each hazardous chemical which they use:  a) At the jobsite, on or about and at times prior to February 5, 2015, the employer did not maintain the Safety Data Sheets, or provide for access to the information contained in the Safety Data Sheets, for "Titebond PROadvantage Subfloor Adhesive" used by employees during the installation of the subfloor of the second floor of a second story residential home, exposing employees to inhalation and absorption hazards.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 24, 2015
Abate by
Mar 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) At the jobsite, on or about and at times prior to February 5, 2015, the employer did not provide for information and training on the use of "Titbond PROadvantage Subfloor Adhesive" that was used by two employees during the installing of the subfloor of the second floor of a two story residential home, exposing the employees to inhalation and absorption hazards.