CHALAN PAGO, GU —
OSHA Inspection: LI GAO CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LI GAO CORPORATION in SOUTH OF MAIMAI STREET AFTER APUSENTO TOWNHOUSES, CHALAN PAGO, GU 96910 (NAICS 236115). OSHA activity number 340369073.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LI GAO CORPORATION
- Site address
- SOUTH OF MAIMAI STREET AFTER APUSENTO TOWNHOUSES
- City
- CHALAN PAGO
- State
- GU
- ZIP
- 96910
- Mailing
- PO BOX 27552, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.300 B01
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): When power operated tools were designed to accommodate guards, they were not equipped with such guards when in use: a) On February 11, 2015, inside the house, there was no guard for the 13 inch diameter abrasive wheel on a Makita cut off saw, model 2416S used the cut concrete blocks.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.451 B01
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds were not fully planked or decked between the front uprights and the guardrail supports: a) On February 11, 2015, near the backside of the house, the 4.3 foot wide platform on the double wood pole scaffold was not fully planked as there was an opening of about 2 by 3 feet next to the access ladder, exposing employees the hazard of falling from a height of about 12.75 feet.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.451 G01
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: a) On February 11, 2015, near the backside of the house, fall protection was not provided for employees on the 4.3 foot wide platform on the double wood pole scaffold, exposing employees the hazard of falling from a height of about 12.75 feet.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.452 A02
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1926.452(a)(2): Crossbracing was not installed between the inner and outer sets of poles on double pole scaffolds: a) On February 11, 2015, near the backside of the house, the double wood pole scaffold had no crossbracing installed between the inner and outer sets of poles on the double poles, exposing employees the hazard of falling from a height of about 12.75 feet.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1926.452 A03
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(a)(3): Diagonal bracing in both directions was not installed across the entire inside face of double-pole scaffolds used to support loads equivalent to a uniformly distributed load of 50 pounds (222 kg) or more per square foot (929 square cm): a) On February 11, 2015, near the backside of the house, the double wood pole scaffold had no diagonal bracing installed across the inside face of the double poles, exposing employees the hazard of falling from a height of about 12.75 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 A07
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(a)(7): Runners were not supported by bearing blocks securely attached to the poles: a) On February 11, 2015, near the backside of the house, the double wood pole scaffold runners were not supported by bearing blocks securely attached to the poles, exposing employees the hazard of falling from a height of about 12.75 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 A08
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(a)(8): Braces, bearers, and runners shall not be spliced between poles: a) On February 11, 2015, near the backside of the house, the double wood pole scaffold had the runners spliced between the poles, exposing employees the hazard of falling from a height of about 12.75 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 A09
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(a)(9): Where wooden poles were spliced, the ends were not squared and the upper section did not rest squarely on the lower section. Wood splice plates were not provided on at least two adjacent sides, and did not extend at least 2 feet (0.6 m) on either side of the splice, overlap the abutted ends equally, and have at least the same cross-sectional areas as the pole. Splice plates of other materials of equivalent strength may be used: a) On February 11, 2015, near the backside of the house, the double wood poles were spliced by overlapping them and nailing them together, exposing employees the hazard of falling from a height of about 12.75 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.25 A
- Issued
- Mar 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, were not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a) On February 11, 2015, in the kitchen on the first level, concrete chips, short pieces of PVC pipe, and pieces of lumber, lay on the floor in the work areas and passageways.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.405 A02 II I
- Issued
- Mar 24, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables were not protected from damage: a) On February 11, 2015, on the asphalt road in front of the house, a 110 VAC extension cord was not protected from damage as it lay on the road and was run over by vehicles. The cord powered portable power tools inside the house such as 110 VAC Makita cut off saws.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at LI GAO Corporation
View LI GAO Corporation's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340369073.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.