Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDWEST SCRAP MANAGEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MIDWEST SCRAP MANAGEMENT in 8116 WILSON RD, KANSAS CITY, MO 64125 (NAICS 423840). OSHA activity number 340444314.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midwest Scrap Management — free Get an email when a new federal OSHA severe-injury report for Midwest Scrap Management is published. One employer, no account, unsubscribe in one click.
Site address
8116 WILSON RD
City
KANSAS CITY
State
MO
ZIP
64125
Mailing
P.O. BOX 4950, KANSAS CITY, MO 64120
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423840
Employees
75
Ownership type
A

6 citations on file for this inspection.

1910.23 A08

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2015
Abate by
Jul 8, 2015
Penalty
Initial $6,300 · Current $4,410 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:  (a) Southwest Conveyor Nonferrous:  Employees were exposed to a fall hazard as there was an opening at the bottom of the east platform stairway.
Recent events (2)
  • — I (S) $4410
  • — Z (S) $6300

1910.36 G02

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 3, 2015
Abate by
Jun 29, 2015
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  (a)  Baler Bulding:  Employees were exposed to fire hazards as the Exit Door and exit access on the north side was blocked by metal and other materials.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.147 C05 II D

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 3, 2015
Abate by
Jul 8, 2015
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):  (a) Tower Shredder Electrical Panels:  Two maintenance employees had locked out a motor for the Center Conveyor and the tag did not identify who had applied the devices.
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.157 E03

Serious Gravity 5 3 instances 9 exposed
Issued
Jun 3, 2015
Abate by
Jul 8, 2015
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a) Center Conveyor, Upper Level:  Employees were exposed to fire hazards, such as, but not limited to, the Badger Fire Protection portable fire extinguisher on the North Side had not had an annual inspection since August 2013.  (b) Roof Level Tower Shredder:  Employees were exposed to fire hazards as the Ansul Sentry Fire Extinguisher on the Roof Level had not had an annual inspection since October 2012.  (c)  Shredder Control Booth:  Employees were exposed to fire hazards as the Kidde Halon 1211 fire extinguisher had not had an annual inspection since May 2013.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.304 G05

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 3, 2015
Abate by
Jul 8, 2015
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) Cooling Tower:  Employees were exposed to electrical hazards as the extension cord used to keep the pipes warm was not grounded as the grounding pin was absent.  (b) Nonferrous Building Breakroom:  Employees were exposed to electrical hazards as the refrigerator in the Breakroom was not grounded as the grounding pin was absent.  (c) Baler Room:  Employees were exposed to electrical hazards as the Husky light was not grounded as the grounding pin was absent.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.305 G02 III

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 3, 2015
Abate by
Jul 8, 2015
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a)  Center Conveyor, Upper Level:  Employees were exposed to electrical hazards as there was not adequate strain relief to the Weg Motor on the northeast side of the upper level.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

View Midwest Scrap Management's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340444314.