Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDWEST SCRAP MANAGEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MIDWEST SCRAP MANAGEMENT in 503 SE BRANNER ST., TOPEKA, KS 66607 (NAICS 423930). OSHA activity number 344183132.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midwest Scrap Management — free Get an email when a new federal OSHA severe-injury report for Midwest Scrap Management is published. One employer, no account, unsubscribe in one click.
Site address
503 SE BRANNER ST.
City
TOPEKA
State
KS
ZIP
66607
Mailing
503 SE BRANNER ST., TOPEKA, KS 66607
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
13
Ownership type
A

11 citations on file for this inspection.

1910.212 A01

Deleted Serious Gravity 5 4 instances 9 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $9,377 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Employees were exposed to caught-in hazards. Employees working with and around the following equipment were exposed to injury associated with inadequate machine guarding:  a) Maintenance shop drill press had an unguarded rotating chuck.  b) Maintenance shop band saw had unguarded sections of the unused portion of the blade.  c) A floor fan in the maintenance shop back entranceway had an unguarded rotating shaft.  d) A floor fan in the maintenance shop close to the electrical panels had an approximate 6 inch diameter hole in the center, allowing access to the rotating parts of the fan blade assembly.
Recent events (3)
  • — F (S) $0
  • — C (S) $9377
  • — Z (S) $9377

1910.215 A04

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Aug 28, 2019
Penalty
Initial $9,377 · Current $0 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  Employees were exposed to struck-by hazards. The work rest on the bench grinder located in the maintenance shop was not adjusted close enough to the grinding wheel. The distance between the abrasive wheel periphery and the adjustable work rest was approximately three eighths of an inch.
Recent events (3)
  • — F (S) $0
  • — C (S) $9377
  • — Z (S) $9377

1910.215 B09

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Aug 28, 2019
Penalty
Initial $9,377 · Current $0 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  The employees were exposed to struck-by hazards. The tongue guard for the bench grinder located in the maintenance shop was not adjusted close enough to the grinding wheel. The distance between the abrasive wheel periphery and the adjustable tongue safety guard was approximately half an inch.
Recent events (3)
  • — F (S) $0
  • — C (S) $9377
  • — Z (S) $9377

1910.219 D01

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $7,500 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Employee(s) were exposed to in-going nip point hazards. Employee(s) working with the following equipment were exposed to unguarded pulleys and their in-going nip points: a) The drill press in the maintenance shop had an unguarded pulley approximately 65 inches from the floor.  b) The band saw in the maintenance shop had an unguarded pulley approximately 24 inches from the floor.
Recent events (3)
  • — F (S) $0
  • — C (S) $7500
  • — Z (S) $7500

1910.219 E03 I

Deleted Serious Gravity 5 2 instances 1 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  Employee(s) were exposed to in-going nip point hazards. Employee(s) working with the following equipment were exposed to unguarded belts and their in-going nip points: a) The drill press in the maintenance shop had an unguarded belt approximately 65 inches from the floor.  b) The band saw in the maintenance shop had an unguarded belt approximately 24 inches from the floor.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.253 B02 II

Deleted Serious Gravity 5 2 instances 9 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $7,500 · Current $0 Reduced

Hazardous substances 8890

29 CFR 1910.253(b)(2)(ii):   Cylinders were not stored in areas to ensure that the cylinders would not be knocked over:  Employees were exposed to fire and struck-by hazards. Two compressed gas cylinders were stored in undesignated areas without supporting straps or any other means of securing the cylinders from being knocked over. One acetylene cylinder was located inside the maintenance shop and a propane cylinder was located outside the maintenance shop dock entrance. Employees working in and around these areas were exposed to fire and struck-by hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $7500
  • — Z (S) $7500

1910.253 B02 IV

Deleted Serious Gravity 5 3 instances 9 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $7,500 · Current $0 Reduced

Hazardous substances 8890

29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  Employees were exposed to fire and struck-by hazards. One acetylene and two propane cylinders located outside the maintenance shop dock entrance were stored without protective valve caps. Employees working in and around these areas were exposed to fire and struck-by hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $7500
  • — Z (S) $7500

1910.253 B04 I

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $9,377 · Current $0 Reduced

Hazardous substances 8890

29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire;   Employees were exposed to fire and explosion hazards. Employees working around improperly stored compressed gas cylinders outside the maintenance shop loading dock were exposed to accelerated fire and explosion hazards. Outside the maintenance shop loading deck, oxygen cylinders were stored immediately next to propane and acetylene compressed gas cylinders and were not separated by a 1 hour, 5 foot tall fire rated wall.
Recent events (3)
  • — F (S) $0
  • — C (S) $9377
  • — Z (S) $9377

1910.254 B04 IV

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $9,377 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.254(b)(4)(iv): Terminals for welding leads were not protected from accidental contact by personnel or metal objects:  Employees were exposed to electrical hazards. Employees using the Lincoln IDEALARC CV-400 arc welder in the maintenance shop were exposed to electrical shock. The welding leads for the Lincoln IDEALARC CV-400 arc welder in the maintenance shop were not guarded from accidental contact.
Recent events (3)
  • — F (S) $0
  • — C (S) $9377
  • — Z (S) $9377

1910.303 B01

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $9,377 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  Employees were exposed to electrical hazards. The insulation and plug for a floor fan in the material handling building was damaged and previously repaired with electrical tape. The electrical tape was damaged and falling off, exposing employees to the live conductors without protective insulation. Employees operating and adjusting the fan were exposed to electrical shock hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $9377
  • — Z (S) $9377

1910.304 G05

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Aug 28, 2019
Abate by
Sep 19, 2019
Penalty
Initial $9,377 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  Employees were exposed to electrical hazards. Employees operating or adjusting a floor fan in the material handling building were exposed to electrical shock injuries associated with inadequate grounding. The plug for a floor fan in the material handling building was missing the ground-pin.
Recent events (3)
  • — F (S) $0
  • — C (S) $9377
  • — Z (S) $9377

View Midwest Scrap Management's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344183132.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.