WASHINGTON, DC —
OSHA Inspection: OSCAR CRUZ CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OSCAR CRUZ CONSTRUCTION in 746 19TH STREET, NE, WASHINGTON, DC 20002 (NAICS 238130). OSHA activity number 340471432.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OSCAR CRUZ CONSTRUCTION
- Site address
- 746 19TH STREET, NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20002
- Mailing
- 7716 LAKE DRIVE, MANASSAS, VA 20111
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.701 B
- Issued
- Jun 25, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: (a) Front of Building Ground - Workers were conducting framing activities and storing equipment/construction materials beside two unguarded rebars in which they could have tripped onto, on or about March 17, 2015.
Recent events (1)
- — Z (S) $2000
1926.1052 C01 I
- Issued
- Jun 25, 2015
- Abate by
- Jul 1, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: (a) 2nd Floor Stairway - Workers were using a stairway with nine risers and no handrail to conduct framing work and were exposed to a 10 feet 2 inches fall hazard on or about March 17, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $1600
1926.1052 C01 II
- Issued
- Jun 25, 2015
- Abate by
- Jul 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: 2nd Floor Stairway - Workers were using a stairway with nine risers and no stairrail to conduct framing work and were exposed to a 10 feet 2 inches fall hazard on or about March 17, 2015. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Jun 25, 2015
- Penalty
- Initial $5,600 · Current $5,600
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Rear, 2nd floor - Work was observed in an unguarded window opening loading wood without using fall protection and was exposed to 15 feet 7 inches fall hazard onto the gravel, wood, and cinder block below, on or about March 18, 2015. (b) Rear, 3rd Floor - Workers were conducting framing activities near unguarded window openings with ledges 21 inches from the floor, without using fall protection and were exposed to a 26 feet 7 inches fall hazard onto the wood, gravel and cinder block below, on or about March 17, 2015. (c) 3rd Floor - Workers were conducting framing activities while working off of a platform and were exposed to a 10 feet 10 inches fall hazard without using fall protection, on or about March 17, 2015. Oscar Cruz Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1042573 citation number 1, item number 1 and was affirmed as a final order on 4/16/2015, with respect to a workplace located at 911 12th Street, NE Washington, DC 20002. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- — Z (R) $5600
More inspections at Oscar Cruz Construction