WASHINGTON, DC —
OSHA Inspection: OSCAR CRUZ CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OSCAR CRUZ CONSTRUCTION in 528 KENNEDY STREET, NW, WASHINGTON, DC 20011 (NAICS 238130). OSHA activity number 342466174.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OSCAR CRUZ CONSTRUCTION
- Site address
- 528 KENNEDY STREET, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20011
- Mailing
- 7716 LAKE DRIVE, MANASSAS, VA 20111
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.1053 B01
- Issued
- Sep 15, 2017
- Abate by
- Sep 21, 2017
- Penalty
- Initial $4,780 · Current $4,780
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Stairway Between the Fourth and Fifth Floor - Employees were using a portable job made ladder to gain access to the fifth floor and the top of the ladder extended only 10 inches above the landing surface, exposing employees to a 9 feet, 4 inch fall, on or about 07/13/2017. Oscar Cruz was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.1053(b)(1), which was contained in OSHA inspection number 1214330, citation number 1, item number 2, and was affirmed as a final order on June 01, 2017, with respect to a workplace located at 1609 Lewis Street, NW Washington DC. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (R) $4780
1926.501 B13
- Issued
- Sep 15, 2017
- Abate by
- Sep 21, 2017
- Penalty
- Initial $41,828 · Current $41,828
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Fifth Floor - Employees were standing near an open edge while installing plywood decking, not using fall protection and exposed to a thirty eight feet, four inch fall hazard, on or about 07/13/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (W) $41828
1926.405 G02 III
- Issued
- Sep 15, 2017
- Abate by
- Sep 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a) Fourth Floor - An employee was using a Milwaukee 7 1/4" portable electric saw to cut wood framing members and the cord had been severed and spliced, 120 volt 15 amp service, on or about 07/13/2017. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (O) $0
More inspections at Oscar Cruz Construction
View Oscar Cruz Construction's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342466174.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.