Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE SKYDYNE COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE SKYDYNE COMPANY in 100 RIVER ROAD, PORT JERVIS, NY 12771 (NAICS 332439). OSHA activity number 340561034.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Skydyne Company — free Get an email when a new federal OSHA severe-injury report for The Skydyne Company is published. One employer, no account, unsubscribe in one click.
Establishment
THE SKYDYNE COMPANY
Site address
100 RIVER ROAD
City
PORT JERVIS
State
NY
ZIP
12771
Mailing
100 RIVER ROAD, PORT JERVIS, NY 12771
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332439
Employees
42
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 15, 2015
Abate by
Jun 30, 2015
Penalty
Initial $3,500 · Current $1,634 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:      a) Facility - On or prior to April 16, 2015, for machines and equipment. Periodic inspection of the energy control procedure, including but not limited to, the Cincinnati Shear was not conducted.
Recent events (2)
  • — I (S) $1634
  • — Z (S) $3500

1910.212 A01

Serious Gravity 10 2 instances 1 exposed
Issued
May 15, 2015
Abate by
Jun 30, 2015
Penalty
Initial $4,900 · Current $1,633 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Machine Shop Area - On or about April 16, 2015, an employee was exposed to being struck-by metal shavings and caught-in hazards while operating a Pratt & Whitney lathe without a guard protecting the employee from rotating parts and projectiles.      b) Machine Shop Area - On or about April 2, 2015, an employee was exposed to being struck-by metal shavings and caught-in hazards while operating an Enco (Model #: 510-2585) lathe without a guard protecting the employee from rotating parts and projectiles.
Recent events (4)
  • — I $8250
  • — Z $16500
  • — I (S) $1633

1910.212 A03 II

Serious Gravity 10 2 instances 2 exposed
Issued
May 15, 2015
Abate by
Jun 30, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) Press Brake Area - On or about March 16, 2015, the Cincinnati 90-350 Proform Hydraulic Press Brake (Serial No. 52930) was in operation without point of operation guarding.    b) Riveter Area - On or prior to April 10, 2015, the Riveter Machine (Milford Rivet Co, Model S310-24, Serial 2339) was in operation without point of operation guarding.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.334 A02 I

Serious Gravity 1 2 instances 2 exposed
Issued
May 15, 2015
Abate by
Jun 30, 2015
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a) Metal Fabrication Area - On or prior to April 16, 2015, two extension cords were plugged into junction boxes that were being used as permanent wiring to power two DeWalt chop saws.    b) Assembly Area - On or prior to April 16, 2015, an extension cord plugged into a junction box was being used as permanent wiring to power a riveter. 29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    a) Metal Fabrication Area - On or prior to April 16, 2015, an extension cord with visible insulation damage to the cord was in use powering a DeWalt chop saw.    b) Press Brake Area - On or about April 16, 2015, a foot pedal with visible insulation damage to the cord was in use on the Cincinnati 90-350 Proform Hydraulic Press Brake (Serial No. 52930).
Recent events (2)
  • — I (S) $1633
  • — Z (S) $2100

View The Skydyne Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340561034.