BARRIGADA, GU —
OSHA Inspection: PMV DESIGNERS BUILDERS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PMV DESIGNERS BUILDERS in BELLO ROAD, PERMIT # B14000763, BARRIGADA, GU 96921 (NAICS 236116). OSHA activity number 340578020.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PMV DESIGNERS BUILDERS
- Site address
- BELLO ROAD, PERMIT # B14000763
- City
- BARRIGADA
- State
- GU
- ZIP
- 96921
- Mailing
- P.O. BOX 9551, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 14
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.95 A
- Issued
- May 29, 2015
- Abate by
- Jun 4, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. Construction site, permit #B14000763 - Employees were observed not wearing protective eyewear at the work site; one employee had been cutting wood with a Makita circular saw and another was rolling latex interior paint overhead.
Recent events (1)
- — Z (S) $1200
1926.404 B01 I
- Issued
- May 29, 2015
- Abate by
- Jun 4, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. Construction site, permit #B14000763 - Ground fault circuit interrupter protection or an assured equipment grounding conductor program was not used when a 110 VAC Makita circular saw was powered through an extension cord. Employees were exposed to the hazards of contacting electricity.
Recent events (1)
- — Z (S) $1200
1926.701 B
- Issued
- May 29, 2015
- Abate by
- Jun 4, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: Construction site, built-in pool, permit #B14000763 - About 24 number 4 rebar protruding from 24"- 36" above ground were not protected. Employees that placed form work and walk in this area are exposed to impalement hazards.
Recent events (1)
- — Z (S) $1200
1910.1200 G08
- Issued
- May 29, 2015
- Abate by
- Jun 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: (Construction Reference: 1926.59) Construction site, permit #B14000763 - The employer did not maintain all Safety Data Sheets (SDS's) for chemical products being used at the work site such as, but not limited to, Hanson Permanente cement (type 1/11 Portland cement), Customblend grout, and Behr latex paint.
Recent events (1)
- — Z (O) $0
More inspections at PMV Designers Builders
View PMV Designers Builders's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340578020.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.