OSHA Inspection: MARMEN ENERGY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MARMEN ENERGY, INC. in 1820 NORTH PLUM AVENUE, BRANDON, SD 57005 (NAICS 332313). OSHA activity number 340670371.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marmen Energy, INC. — free Get an email when a new federal OSHA severe-injury report for Marmen Energy, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MARMEN ENERGY, INC.
Site address
1820 NORTH PLUM AVENUE
City
BRANDON
State
SD
ZIP
57005
Mailing
1820 NORTH PLUM AVENUE, BRANDON, SD 57005
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
197
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 1, 2015
Abate by
Oct 7, 2015
Penalty
Initial $6,930 · Current $6,930
Section 5(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards:    (a) On or about May 29, 2015, for the employees exposed to struck-by hazards while lifting and moving a CMS Buggy utilizing rigging equipment with a missing hook throat latch at 1820 North Plum Avenue, Brandon, South Dakota.  Abatement Note: Among other methods, one feasible and acceptable abatement method to correct the hazard would be for the employer to ensure rigging equipment hooks have throat latches as referenced in ASME B30.10-2014, HOOKS, Section 10-2.10: INSPECTION, REMOVAL, AND REPAIR, paragraph 10-2.10.5 Removal Criteria which states Hooks shall be removed from service if damage such as the following is visible and shall only be returned to service when approved by a qualified person: (i) Inoperative latch (if provided)  any damaged latch or malfunctioning latch that does not close the hooks.
Recent events (1)
  • — Z (S) $6930

1910.179 B08

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 1, 2015
Abate by
Oct 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.179(b)(8): An employee other than designated personnel were permitted to operate a crane:  (a) On or about May 29, 2015, for the employee who sustained injuries while utilizing a Wolverine 50 ton gantry crane to lift and movie a CMS Buggy at 1820 North Plum Avenue, Brandon, South Dakota.
Recent events (1)
  • — Z (S) $0

View Marmen Energy, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340670371.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.