DANVILLE, IL —
OSHA Inspection: VISCOFAN USA, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of VISCOFAN USA, INC. in 915 N. MICHIGAN AVE., DANVILLE, IL 61834 (NAICS 326121). OSHA activity number 340735646.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VISCOFAN USA, INC.
- Site address
- 915 N. MICHIGAN AVE.
- City
- DANVILLE
- State
- IL
- ZIP
- 61834
- Mailing
- 915 N. MICHIGAN AVE., DANVILLE, IL 61834
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326121
- Employees
- 319
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A02
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: Employees were exposed to rotating parts, nip points and other hazards on the slurry pumps because the lid to the cages around the slurry pumps was not secured and could be opened at anytime without the use of tools.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
1910.219 F01 I
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.219(f)(1)(i): Gears were not guarded by a complete enclosure. Employees were exposed to rotating gears on Slurry Pump #7 because the expanded metal enclosure around the pump had a large hole on the side thus exposing the rotating gears.
Recent events (2)
- — I (S) $2500
- — Z (S) $5000
1910.219 M01 I
- Issued
- Aug 13, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(m)(1)(i): Standard conditions were not secured by the use of the following materials: expanded metal, perforated or solid sheet metal, wire mesh on a frame of angle iron, or iron pipe securely fastened to floor or to frame of machine: Employees were exposed to mechanical power-transmission belts, pulleys and gears on Slurry Pump #7 because the expanded metal enclosure around the pump was not securely fastened to the floor or machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Viscofan USA, INC.
View Viscofan USA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326121)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340735646.