Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VISCOFAN USA INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VISCOFAN USA INC. in 915 N MICHIGAN AVE, DANVILLE, IL 61834 (NAICS 311612). OSHA activity number 345788806.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Viscofan USA INC. — free Get an email when a new federal OSHA severe-injury report for Viscofan USA INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VISCOFAN USA INC.
Site address
915 N MICHIGAN AVE
City
DANVILLE
State
IL
ZIP
61834
Mailing
915 N MICHIGAN AVE, DANVILLE, IL 61834
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311612
Employees
312
Ownership type
A

2 citations on file for this inspection.

1910.219 C03

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 21, 2022
Abate by
Aug 19, 2022
Penalty
Initial $9,687 · Current $5,812 Reduced
29 CFR  1910.219(c)(3):  Vertical or inclined shafting seven (7) feet or less from floor or working platform was not enclosed with stationary casing(s) in accordance with paragraphs (m) and (o) of this section:  On or about February 16, 2022, employees working in the Slurry room were exposed to entanglement hazards because:  a.  the vertical drive shaft used to turn the Mixer for Dissolver #3 was not guarded or enclosed in accordance with the standard.  b.  the vertical drive shaft used to turn the Mixer for Dissolver #7 was not guarded or enclosed in accordance with the standard.
Recent events (2)
  • — I (S) $5812.2
  • — Z (S) $9687

1910.219 F01

Serious Gravity 10 2 instances 1 exposed
Issued
Jul 21, 2022
Abate by
Aug 19, 2022
Penalty
Initial $13,559 · Current $8,135 Reduced
29 CFR  1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii):  On or about February 16, 2022, employees working in the Cellulose Extrusion Department were exposed to amputation and entanglement hazards because:  a.  the drive gears located in Bay 1, powering  the PM1, PM3 and "black  strip" pumps were not guarded or enclosed in accordance with the standard.  b.  the drive gears located in Bay 3, powering the PM7 pumps were not guarded or enclosed in accordance with the standard.
Recent events (2)
  • — I (S) $8135.4
  • — Z (S) $13559

View Viscofan USA INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345788806.